OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATIONAL TEMPERATURE

INDOOR HUMIDITY

IF OUT OF CONDITIONS

 

INDOOR

OUTDOOR

 

 

 

 

 

 

 

09/12

10˚C to 43˚C

 

Condensation may occur on

 

 

 

 

the indoor unit with risk to

 

COOLING

16˚C to 32˚C

 

 

80% or less

ENGLISH

18/24

-10˚C to 43˚C

have either water blow off or

 

 

 

 

 

 

 

 

 

 

drops on the floor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09/12

-10˚C to 24˚C

 

Internal protection triggers

 

HEATING

27˚C or less

 

 

-

and the air conditioner will

 

 

 

 

 

 

18/24

-15˚C to 24˚C

 

stop.

 

 

 

 

 

 

 

 

 

 

09/12

10˚C to 43˚C

 

Condensation may occur on

 

 

 

 

the indoor unit with risk to

 

DRYING

16˚C to 32˚C

 

 

-

 

18/24

-10˚C to 43˚C

have either water blow off or

 

 

 

 

 

 

 

 

drops on the floor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition.

If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.