Samsung AR09HSFTKWQNET manual ErP InformationAC Product, AR09HSFTKWQN / AR09HSFTKWQX

Models: AR09HSFTKWQXET AR09HSFTKWQNET

1 1
Download 1 pages 28.11 Kb
Page 1
Image 1

ErP Information(AC Product)

 

 

 

AR09HSFTKWQN / AR09HSFTKWQX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

 

cooling

 

Y

 

Average

 

 

Y

 

heating

 

Y

 

Warmer

 

 

Y

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

symbol

value

 

unit

Item

symbol

 

value

 

unit

Design load

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Pdesignc

2,5

 

kW

cooling

SEER

 

5,6

 

-

heating/Average

 

Pdesignh

2,5

 

kW

heating/Average

SCOP/A

 

3,8

 

-

heating/Warmer

 

Pdesignh

2,5

 

kW

heating/Warmer

SCOP/W

 

4,0

 

-

heating/Colder

 

Pdesignh

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

Declared capacity(*) for

cooling, at indoor temperature

 

Declared energy efficiency ratio(*), at indoor temperature

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

Item

 

symbol

value

 

unit

Item

symbol

 

value

 

unit

Tj = 35 ℃

 

Pdc

2,5

 

kW

Tj = 35 ℃

EERd

 

3,5

 

-

Tj = 30 ℃

 

Pdc

1,9

 

kW

Tj = 30 ℃

EERd

 

4,9

 

-

Tj = 25 ℃

 

Pdc

1,2

 

kW

Tj = 25 ℃

EERd

 

7,0

 

-

Tj = 20 ℃

 

Pdc

1,2

 

kW

Tj = 20 ℃

EERd

 

9,0

 

-

Declared capacity(*) for

heating/Average

season, at

indoor

 

Declared coefficient of

performance(*)/Average season,

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

Tj = - 7 ℃

 

Pdh

2,3

 

kW

Tj = -7

COPd

 

2,7

 

-

Tj = 2 ℃

 

Pdh

1,4

 

kW

Tj = 2 ℃

COPd

 

3,8

 

-

Tj = 7 ℃

 

Pdh

1,0

 

kW

Tj = 7 ℃

COPd

 

4,7

 

-

Tj = 12 ℃

 

Pdh

1,0

 

kW

Tj = 12 ℃

COPd

 

5,5

 

-

Tj = bivalent

 

Pdh

2,5

 

kW

Tj = bivalent

COPd

 

2,4

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

2,5

 

kW

Tj = operating limit

COPd

 

2,4

 

-

Declared capacity(*) for

heating/Warmer

season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

Tj = 2 ℃

 

Pdh

2,5

 

kW

Tj = 2 ℃

COPd

 

2,8

 

-

Tj = 7 ℃

 

Pdh

1,5

 

kW

Tj = 7 ℃

COPd

 

4,5

 

-

Tj = 12 ℃

 

Pdh

1,0

 

kW

Tj = 12 ℃

COPd

 

5,1

 

-

Tj = bivalent

 

Pdh

2,5

 

kW

Tj = bivalent

COPd

 

2,8

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

2,5

 

kW

Tj = operating limit

COPd

 

2,4

 

-

Declared capacity(*) for

heating/Colder

season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

Tj = -7

 

Pdh

-

 

kW

Tj = -7

COPd

 

-

 

-

Tj = 2 ℃

 

Pdh

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

 

Pdh

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

 

Pdh

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

 

Pdh

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Tj = -15

 

Pdh

-

 

kW

Tj = -15

COPd

 

-

 

-

Bivalent temperature

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

 

Tbiv

-10

 

heating/Average

Tol

 

-10

 

heating/Warmer

 

Tbiv

2

 

heating/Warmer

Tol

 

-10

 

heating/Colder

 

Tbiv

-

 

heating/Colder

Tol

 

-

 

Cycling interval capacity

 

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

 

Pcycc

-

 

kW

for cooling

EERcyc

 

-

 

-

for heating

 

Pcych

-

 

kW

for heating

COPcyc

 

-

 

-

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

co-efficient

 

Cdc

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

Electric power input in

power modes

other than

 

 

Annual electricity consumption

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

 

POFF

0,0

 

kW

cooling

QCE

 

156

 

kWh/a

standby mode

 

PSB

0,0

 

kW

heating/Average

QHE

 

921

 

kWh/a

thermostat-off mode

 

PTO

0,1

 

kW

heating/Warmer

QHE

 

875

 

kWh/a

crankcase heater

 

PCK

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

N

 

 

 

Sound power level

LWA

 

56,0/59,0

 

dB(A)

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

Y

 

 

 

Rated air flow

-

 

600/1920

 

m3/h

 

 

 

(indoor/outdoor)

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

obtaining more

 

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of

the unit' and 'declared EER/COP' of unit.

(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.

Page 1
Image 1
Samsung AR09HSFTKWQNET, AR09HSFTKWQXET manual ErP InformationAC Product, AR09HSFTKWQN / AR09HSFTKWQX

AR09HSFTKWQXET, AR09HSFTKWQNET specifications

The Samsung AR09HSFTKWQNET and AR09HSFTKWQXET are two standout models in Samsung’s line of air conditioning units, designed to deliver powerful cooling and energy efficiency in residential and commercial spaces. Both models incorporate advanced technologies and user-friendly features that enhance user comfort while minimizing energy consumption.

One of the main features of these units is their use of Digital Inverter Technology. This innovative system maintains the desired temperature without frequent on-off cycling, reducing energy consumption by up to 60% when compared to traditional air conditioners. The Digital Inverter allows the compressor to adjust its speed based on the cooling demand, ensuring a consistent and comfortable environment without dramatic fluctuations in temperature.

In addition to energy efficiency, the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET are equipped with a powerful air filtration system. The Triple Protection Filter not only captures dust and allergens but is also easy to clean and maintain. This means that indoor air quality remains high, making these units particularly suitable for allergy sufferers and those looking for a cleaner living environment.

The design of both models blends seamlessly with any decor, featuring a sleek and modern exterior. The additional LED display allows users to monitor settings easily, further enhancing the user experience. Each model comes with a remote control, enabling the user to adjust temperature and settings from anywhere in the room.

Noise levels are another key characteristic of the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET. These air conditioners operate quietly, making them ideal for bedrooms and workspaces where noise disruption is not welcome. This is further enhanced by the indoor units’ acoustic insulation, which minimizes sound transmission.

Another remarkable aspect is their quick cooling function. With the option to reach the desired temperature rapidly, users can enjoy immediate relief from heat, making these air conditioners perfect for hot climates.

To underscore their commitment to sustainability, Samsung designs these models with eco-friendly refrigerants, further contributing to lower environmental impact while still maintaining high performance.

In summary, the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET embody cutting-edge technology combined with user-centric features. Their energy-efficient operations, advanced air filtration, stylish design, and quiet functioning make them an excellent choice for anyone seeking a dependable and effective cooling solution.