ErP Information(AC Product)

 

 

 

 

 

 

AR24FSFPESNN / AR24FSFPESNX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

 

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

cooling

 

Y

 

Average

 

 

Y

heating

 

Y

 

Warmer

 

 

N

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Design load

 

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Pdesignc

 

6,8

 

kW

cooling

SEER

 

6,1

 

-

heating/Average

Pdesignh

 

5,6

 

kW

heating/Average

SCOP/A

 

3,8

 

-

heating/Warmer

Pdesignh

 

-

 

kW

heating/Warmer

SCOP/W

 

-

 

-

heating/Colder

Pdesignh

 

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

Declared capacity(*) for

cooling, at indoor temperature

 

 

 

Declared energy efficiency ratio(*), at indoor temperature

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Tj = 35 ℃

Pdc

 

6,8

 

kW

Tj = 35 ℃

EERd

 

2,90

 

-

Tj = 30 ℃

Pdc

 

5,3

 

kW

Tj = 30 ℃

EERd

 

4,70

 

-

Tj = 25 ℃

Pdc

 

3,3

 

kW

Tj = 25 ℃

EERd

 

7,1

 

-

Tj = 20 ℃

Pdc

 

1,9

 

kW

Tj = 20 ℃

EERd

 

10,5

 

-

Declared capacity(*) for

heating/Average season, at indoor

 

Declared coefficient of performance(*)/Average season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = - 7 ℃

Pdh

 

5,3

 

kW

Tj = -7

COPd

 

2,6

 

-

Tj = 2 ℃

Pdh

 

3,0

 

kW

Tj = 2 ℃

COPd

 

3,9

 

-

Tj = 7 ℃

Pdh

 

2,0

 

kW

Tj = 7 ℃

COPd

 

4,5

 

-

Tj = 12 ℃

Pdh

 

1,6

 

kW

Tj = 12 ℃

COPd

 

5,2

 

-

Tj = bivalent

Pdh

 

5,6

 

kW

Tj = bivalent

COPd

 

2,3

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

5,6

 

kW

Tj = operating limit

COPd

 

2,3

 

-

Declared capacity(*) for

heating/Warmer season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Declared capacity(*) for

heating/Colder season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = -7

Pdh

 

-

 

kW

Tj = -7

COPd

 

-

 

-

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Tj = -15

Pdh

 

-

 

kW

Tj = -15

COPd

 

-

 

-

Bivalent temperature

 

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

Tbiv

 

-10

 

heating/Average

Tol

 

-10

 

heating/Warmer

Tbiv

 

-

 

heating/Warmer

Tol

 

-

 

heating/Colder

Tbiv

 

-

 

heating/Colder

Tol

 

-

 

Cycling interval capacity

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

Pcycc

 

-

 

kW

for cooling

EERcyc

 

-

 

-

for heating

Pcych

 

-

 

kW

for heating

COPcyc

 

-

 

-

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

co-efficient

Cdc

 

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

Electric power input in

power modes other than

 

 

 

Annual electricity consumption

 

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

POFF

 

0,0

 

kW

cooling

QCE

 

390

 

kWh/a

standby mode

PSB

 

0,0

 

kW

heating/Average

QHE

 

2063

 

kWh/a

thermostat-off mode

PTO

 

0,0

 

kW

heating/Warmer

QHE

 

-

 

kWh/a

crankcase heater

PCK

 

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

 

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

N

 

 

 

Sound power level

LWA

 

62,0/67,0

 

dB(A)

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

Y

 

 

 

Rated air flow

-

 

1020/2400

 

m3/h

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

 

obtaining more

http://www.samsung.com

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

 

(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit.

(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.

Page 1
Image 1
Samsung AR24FSFPESNNEU, AR24FSFPESNXEU manual ErP InformationAC Product, According to Commission Regulation EU No 206/2012