Samsung AW060CM Preparation for Installation, Checkpoints Prior to Installation, G Etting Started

Models: AW050CM AW060CM

1 20
Download 20 pages 47.88 Kb
Page 14
Image 14
G ETTING STARTED

G ETTING STARTED

Preparation for Installation

Always have an assistant to help you. Never attempt to install any air conditioner alone.

You risk the possibility of hurting yourself or injuring others by attempting to install it alone.

Checkpoints Prior to Installation

1 Carefully remove the unit from the packing case and lay it on

the floor and check that all accessories (as indicated) are enclosed.

2 Check the cabinet and front grille of the unit for any defects such as scratches.

3 Be sure to check the power supply.

Refer to the specifications on the label attached to the unit.

Installation Conditions

1Electrical Requirements For personal safety:

This appliance must be properly grounded.

Do not, under any circumstances, cut or remove the third grounding prong from the power cord.

We recommend that you do not use an extension cord or an adapter plug with this appliance.

Do not change the plug on the power cord of this appliance.

Follow national electrical codes or local codes and ordinances.

 

115V

230-208V

230-208V

230-208V

15 AMP circuit

20 AMP circuit

15 AMP circuit

30 AMP circuit

"parallel" type

"perpendicular" type

"tandem" type

"tandem" type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the electric supply provided does not meet the above specifications, call a licensed electrician.

Aluminum house wiring may pose special problems - consult a qualified electrician.

This unit requires a separate circuit, serving only this appliance.