![](/images/backgrounds/360298/360298-08x1.png)
Selecting Energy Saving Mode (Only ✴✴✴✴F3/A3/G3✴✴✴ models)
If you wish to save energy when using the air conditioner,
select the energy saving mode by using the Energy Saver switch. This feature is normally used when the room is unoccupied.
1To select the energy saving mode, set the Energy Saver switch to the ON
position.
Result: The fan and compressor cycle on and off simultaneously.
This results in wider variations of room temperature and humidity.
➢ If you want to run the air conditioner in Fan mode, do not turn the Energy Saver switch on. The Fan mode will not operate when the Energy Saver switch is in the ON position.
2To turn off the energy saving feature, set the Energy Saver switch to the
OFF position.
Result: The fan runs at all times, while the compressor cycles on and off.
Operating Recommendation
Here is a recommendation that you should follow when using your air conditioner.
TopicRecommendation
Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, the air conditioner starts up again automatically.
Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges within which the air conditioner can be used.
| Mode | Indoor Temperature | Outdoor Temperature | Indoor Humidity | |
|
|
|
|
|
|
| Cooling | 21°C to 32°C approx. | 21°C to 43°C approx. | 80% or less | |
|
|
| 21°C to 54°C approx.(Middle East) |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| If the air conditioner is used at... | Then... |
|
| |
| Higher temperature |
| The automatic protection feature may be triggered | ||
|
|
| and the air conditioner stopped. |
|
|
|
|
|
|
| |
| Lower temperature |
| A water leakage or some other malfunction may happen | ||
|
|
| if the heat exchanger freezes. |
|
|
| Higher humidity levels | Water may condense on and drip from the surface of the unit | |||
|
|
| if it is used for long periods. |
|
|
|
|
|
|
|
|