32
INSTALLING THE W ATER DISPENSER LINE
Remove any residual matter inside the purifier. (Model with the purifier)
- Open the main water tap to check whether water
is running through the water tube on the water
inlet side of the purifier.
- If water does not come out through the line,
check whether the tap is open.
- Leave the tap open until clean water is running
out and any residual matter that built up during
manufacturing has been removed.
- If you wish to reassemble the water inlet
and outlet sides of the purifier during purifier
installation, see the reference illustration.
Select the location where the purifier is to install. (Model with the purifier)
- Cut the water line attached to the purifier
to the appropriate place after measuring
the distance between the purifier and the
cold water tap.
COUPLER
SIDE OF
PURIFIER
WATER LINE
PURIFIER
WATER
OUTLET SIDE
OF PURIFIER
WATER INLET
SIDE OF PURIFIER
LINE OUTLET
90 degree
PURIFIER
WATER REFERENCE
WARRANTY INFORMATION
This water line installation is not covered by the refriger-ator
or ice maker manufacturer's warranty.
Follow these instructions carefully to minimise the risk of
expensive water damage.
Note:
If the coupler does not fit on the current tap, go
the nearest authorised service dealer and purchase
the right couplers fittings.

Connect to the water supply line

Connect the water pipe with coupler and tap.
- Close the main water tap.
- Connect coupler “A” to the tap.
- Every join should be protected with sealing tape.
COUPLER “A”
TAP
CAUTION
The water line must be connected
to the cold water pipe.
If it is connected to the hot
water pipe, it may cause the
purifier to malfunction.

For Exterior model

DA99-00494B (EN)-0.7 7/22/04 12:37 PM Page 32