Test instrumentation

 

 

Model name

 

 

Manufacturer

 

 

Serial or Firmware

 

 

Calibration

 

 

 

 

 

 

 

(No./Ver.)

 

 

Date

 

 

 

 

 

 

 

 

 

 

 

 

 

Stopwatch

 

PC90

 

Time Art

TPST003

1st Apr. 2015

 

Power meter

 

WT1806

 

Yokogawa

 

0GAA-B04817

 

30th Mar. 2015

 

Power Source

61605

 

 

Chroma

0GAA-B05037

7th Oct. 2015

1.8Measurement method used

-Measurement condition_1) Picture : no input load, 2) Sound : no input load.

-Deactivate all other network ports that are not under test.

-Ensure that the EUT does not perform a main function and wait for 20 minutes, So that the EUT able to go into the networked mode.

-The EUT standby mode power consumption was monitored for a further period of 5 minutes.

The variation in power consumption over this period is 5%, so the maximum reading of NTW standby mode power as measured by the power analyzer is recorded as the test result

1.9Set-up and circuit for electrical testing ( Insert the picture or diagram of the test configuration )

2. Off mode

2.1 Test result

 

 

Test date

 

 

N/A

 

Power Consumption (W)

 

N/A

 

 

 

 

 

(rounded to the 1st decimal place)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2 Test parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parameters

 

Actual

Limit

parameters

 

Actual

Limit

 

 

 

Ambient temperature ()

 

-

 

Test voltage (V)

 

-

 

 

 

 

Test frequency (Hz)

 

-

 

Total harmonic distortion

 

-

 

 

 

 

 

 

 

 

 

 

(%)

 

 

 

 

 

 

Crest factor

 

-

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.3Description of how the appliance mode was selected or programmed

N/A

3