Samsung RB195ZA**, RB215ZA** Before You Install the water line, Connecting to water supply line

Models: RB195ZA** RB215ZA**

1 20
Download 20 pages 53.42 Kb
Page 13
Image 13
INSTALLATION OF THE WATER DISPENSER LINE

INSTALLATION OF THE WATER DISPENSER LINE

Before You Install the water line

This water line installation is not warranted by the refrigerator or icemaker manufacturer. Follow these instructions carefully to minimize the risk of expensive water damage.

Banging pipes (water banging in the pipes) in house plumbing can cause damage to refrigerator parts and lead to water leakage or flooding. Call a qualified plumber to correct the problem before installing the water supply line to the refrigerator.

To prevent burns and product damage, do not hook up the water line to the hot water line.

Do not install the icemaker tubing in areas where temperatures fall below freezing.

When using any electrical device (such as a power drill) during installation, be sure the device is insulated or wired in a manner to prevent electric shock.

All installations must be in a accordance with local plumbing code requirements.

 

- Water line Kit and water filter are not covered by Samsung Warranty and manufacturer(or dealer, installer)

NOTE

of them should be responsible for the defect and all the loss caused by water filter & water line kit .

-Filter should be replaced according to manufacturer (or dealer)'s instruction.

-To order additional water filters, please contact the manufacturer (or dealer) of the filter.

Connecting to water supply line

- Shut off the main water supply line and turn the Ice maker to the off position.

- Locate the nearest cold drinking water line. - Follow the instructions in the ice maker

installation kit.

-After connecting the water supply with water filter, turn on water supply and flush 4 or more gallons into a bucket to clear the water filter

1.Cold Water line

2.Pipe Clamp. 3.Copper (or Plastic) line 4.Compression Nut 5.Compression Sleeve 6.Shut Off Valve 7.Packing Nut.

Connect the water line to the refrigerator

-Slip the compression nut through the plastic tube.

-After inserting the compression nut into plastic tube, tighten the compression nut onto 1/4” compression fitting(union).

Do not overtighten the compression nut.

NOTE

-Slip the compression ferrule and nut on copper(or plastic) tubing as shown.

After inserting the sleeve, tighten the compression nut onto the compression fitting(union).

-Turn water on and check for any leakege.

Compression

Nut

Before You Install the water line Ferrule

Connecting to water supply lineConnect the water line to the refrigerator Sleeve

- Waterline must be connected to drinkable water only Compression

fitting

Manual backgroundManual background Compression

Nut

- You can purchase the necessary parts through CAMCO service.

NOTE

- Waterline must be connected to drinkable water only

 

 

- Compression fitting and nut will be given inside of ice bucket.