10-5 Diagnosing the main components
| Components | Diagnosing methods and criteria |
|
|
| Location |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure the |
|
|
|
|
|
| Mechanical |
|
| Compressor | Measuring point | Normal |
| Abnormal |
|
| |||
| resistance. |
|
|
|
|
|
| compartment |
| |
| Primary iwre | Approx 10~500㏀ | 0Ω and |
|
| |||||
|
| - Bring the component to cool down |
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
|
| completely before measuring. | Secondary wire | 3~20㏀ |
| ∞Ω |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure the |
|
|
|
|
|
| Mechanical |
|
| P.T.C Relay | resistance. | Normal |
|
| Abnormal |
|
| ||
| - Bring the component to cool down |
|
|
|
|
|
| compartment |
| |
| Approx ∞Ω~㏀ |
| 0Ω and ∞Ω |
|
| |||||
|
|
|
|
|
| |||||
|
| completely before measuring. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure |
|
|
|
|
|
| Electrical |
|
| Condenser | the resistance. | Normal |
|
| Abnormal |
|
| ||
| Approx 10Ω ~ 80㏀ |
| 0Ω and ∞Ω |
| equipment box |
| ||||
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure |
|
|
|
|
|
|
|
|
|
| the resistance. | Normal |
|
| Abnormal |
| Mechanical |
| |
|
| - Bring the component to cool down |
|
|
|
| compartment |
| ||
| Overload relay | Approx 200㏀ |
| 0Ω and ∞Ω |
|
| ||||
| completely before measuring. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure |
|
|
|
|
|
| Mechanical |
| |
| the resistance. |
|
|
|
|
|
| compartment |
| |
| Normal |
|
| Abnormal |
|
| ||||
| & |
|
|
|
| |||||
| - Bring the component to cool down |
|
|
|
|
|
| Freezing |
| |
| Approx 100Ω~20㏀ |
| 0Ω and ∞Ω |
|
| |||||
| completely before measuring. |
|
| compartment |
| |||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure |
|
|
|
|
|
|
|
|
| Rotating blade | the resistance. | Normal |
|
| Abnormal |
| Refigerating |
| |
|
| - Bring the component to cool down | Approx 10Ω~20㏀ |
| 0Ω and ∞Ω |
|
| |||
|
|
| compartment |
| ||||||
| completely before measuring. |
|
|
| ||||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure |
|
|
|
|
|
|
| |
|
| Measuring point | Normal |
| Abnormal |
| Between the |
| ||
|
| the resistance. |
|
|
|
|
|
|
| |
| Door switch | A B contact point |
|
|
| 0Ω and |
|
| ||
|
|
|
|
| upper and the |
| ||||
|
|
|
|
|
|
|
|
| ||
|
| When the switch is on | Approx 200MΩ | ∞Ω |
|
| ||||
|
|
|
| lower doors |
| |||||
|
|
| by the contact |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Use the tester to measure | Measuring point | Normal |
| Abnormal |
| Electrical |
| |
|
| the resistance. | Between terminals | Approx 200㏀ | 0Ω and |
|
| |||
| Defrost timer |
| equipment box |
| ||||||
|
| Temperature fuse | Approx 10Ω~300㏀ | ∞Ω |
|
| ||||
|
|
|
|
| ||||||
|
|
| terminal |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure |
|
|
|
|
|
| Lower EVAP |
|
|
| Normal |
|
| Abnormal |
|
| |||
| Defrost heater | the resistance. |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
| Approx 3㏀~6㏀ |
| ∞MΩ~ ∞Ω |
|
|
| ||||
|
| - Bring the component to cool down |
|
|
|
| ||||
|
| completely before measuring. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Use the tester to measure |
|
|
|
|
|
|
| |
| Bimetal | Measuring point | Normal |
| Abnormal |
|
|
| ||
| the resistance. | Bimetal terminal |
|
|
|
|
| EVAP |
| |
| Temperature fuse |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
| Temperature fuse | Approx 200MΩ | ∞Ω~ ∞Ω |
|
| ||||
|
|
|
|
|
| |||||
|
|
| terminal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-15- |