Temperature and Humidity Ranges

The following table indicates the temperature and humidity ranges within which the air conditioner can be used.

If the air conditioner is used at...

Then...

 

 

 

 

High temperatures

The automatic protection feature may be triggered and the air conditioner stopped.

 

 

 

 

Low temperatures

A water leak or some other malfunction may occur if the heat exchanger freezes.

 

 

 

 

High humidity levels

Water may condense on and drip from the surface of the indoor unit if it is used for long periods.

 

 

 

 

 

 

 

 

Mode

Outdoor Temperature

Indoor Temperature

Indoor Humidity

Heating

0°C to 24°C approx.

27°C or less

-

Cooling

21°C to 43°C approx.

18°C to 32°C approx.

80% or less

Drying

18°C to 43°C approx.

18°C to 32°C approx.

-

If the heating operation is used at below 0°C(outdoor temperature) then, it does not heat at its full capacity. If the cooling operation is used at over 33°C(indoor temperature) then, it does not cool at its full capacity.

Cleaning Your Air Conditioner

✴✴✴07/09/12✴✴✴

To get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter.

IMPORTANT

Before cleaning your air conditioner, ensure that you

 

have switched off the breaker used for the unit.

✴✴✴18/24✴✴✴

Hook

 

 

Body

Front grille

groove

SH✴✴VCD / SH✴✴AC✴✴ / AQ(T)✴✴CR(M)✴✴

Hook

Body

groove

Front grille

1Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit.

2✴✴✴07/09/12✴✴✴, SH✴✴VCD, SH✴✴AC✴✴, AQ(T)✴✴CR(M)✴✴

Disassemble the front grille by pulling it forwards.

✴✴✴18/24✴✴✴

The removal of the front grille facilitates your cleaning the air conditioner. After opening the front grille, lift up to the max, and pull to release them and vice versa.

3✴✴✴07/09/12✴✴✴

Hold the edge of the air filter under the front grille and pull to release them.

✴✴✴18/24✴✴✴, SH✴✴VCD, SH✴✴AC✴✴, AQ(T)✴✴CR(M)✴✴

Lift out the bottom edge of the air filters and pull down to release them.

4Remove all dust on the air filters with a vacuum cleaner or brush.

55-1✴✴✴18/24✴✴✴, SH✴✴VCD, SH✴✴AC✴✴, AQ(T)✴✴CR(M)✴✴

When you have finished, insert the top part of the filters into their slot and push down on the bottom edge until they click into place.

5-2 Clean the front panel with a damp cloth and mild detergent (do NOT use benzene, solvents or other chemicals).

6 Reassemble the air filters and the front grille.

Note

If you have not used the air conditioner for a long period of time, set the fan

 

going for three to four hours to dry the inside of the air conditioner thoroughly.

E-22

Page 22
Image 22
Samsung SH09VAD Temperature and Humidity Ranges, Cleaning Your Air Conditioner, If the air conditioner is used at Then