8. Designation of Main Components

8-1 Normal / Reverse Revolution of Motor and R. P. M. Control

8

Rotor

9

+

 

 

 

CW

5

Stator coil

10

-

 

 

 

8

Rotor

9

+

 

 

 

 

 

5

CCW

 

 

-

 

 

 

 

Stator coil

10

 

5

 

 

 

 

<Figure1>

 

 

1

2

3

4

5

6

7

8

9

10

HIGH-SPEED

 

TACHO

 

MIDDLE-SPEED

 

PROTECTOR (150 C)

ROTOR

 

 

 

 

 

 

STATOR

 

 

 

 

 

 

 

 

 

 

STATOR

 

 

 

 

WASHING MOTOR

 

H

 

 

 

 

 

 

 

<Figure2>

 

 

<Figure3>

 

 

 

 

 

 

 

STATOR(5.10)

STATOR(5.1)

ROTOR(8.9)

TACHO(3.4)

PROTECTOR(6.7)

“H”(mm)

Code-No

Remark

 

 

 

 

 

 

 

 

 

Resistance value

1.64 Ω

0.91 Ω

1.9 Ω

42.7 Ω

0

52

DC31-10181A

A

 

 

 

 

 

 

 

 

 

 

2.07 Ω

0.90 Ω

2.35 Ω

42.7 Ω

0

45

DC31-00002C

B

 

 

 

 

 

 

 

 

 

Rated value

 

 

 

220~240V / 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

8-2 Door safety Device

220/240V

220/240V

ED 1.0%

ED 1.0%

KB 1s

KB 1s

SD 100s

SD 100s

 

 

12A 125~250V AC

DC61-00115A

Solenoid

SOLENOID Coil Resistance 210 Ω ± 10%

DC61-00122A

8-3 Heater

1)Capacity : AC 230V/2000W

2)Location : Bottom of TUB

3)

Function : Raise the water temperature

Thermistor

 

supplied at the wash process.

 

4)

Resistance value : 23Ω ~ 29Ω

 

5) Thermo Fuse : 128°C

SAMSUNG ELECTRONICS CO., LTD

11

Page 14
Image 14
Samsung SWV-1200F service manual Designation of Main Components, Normal / Reverse Revolution of Motor and R. P. M. Control