MODEL

 

AS18A9(0)RCF / AS18A9(0)RCFD

AS24A1(2)RC / AS24A1(2)RCD

 

 

 

 

 

Performance

Capacity Cooling

Btu/h

18000

23500

Ratings

 

 

 

 

SEER

 

10.0

10.0

 

 

 

 

 

 

 

 

Moisture Removal

Pts/h

4.9

5.4

 

 

 

 

 

 

Air FLOW(Cooling, HIGH)

CFM

456

477

 

 

 

 

 

 

Sound Rating-Outdoor

dB

57

59

 

 

 

 

 

Electrical

Power source

 

208-230V~, 60Hz

208-230V~, 60Hz

Data

 

 

 

 

Min.Ampacity

A

8.0

10.5

 

 

 

 

 

 

 

Cooling Watts

W

1770

2350

 

 

 

 

 

Refrigeration

Connections

 

Flare

Flare

Lines

 

 

 

 

Liquid Line O. D.

inch(mm)

41 (6.35)

41 (6.35)

 

 

 

 

 

 

Suction Line O.D.

inch(mm)

21 (12.70)

85 (15.88)

 

 

 

 

 

 

Factory Pre-charge

ft(m)

2443 (7.5)

1621 (5.0)

 

 

 

 

 

 

Max. Line length

ft(m)

4941 (15.0 )

6521 (20.0)

 

 

 

 

 

 

Max. Height Difference

ft(m)

23(7.0)

2641 (8.0 )

 

 

 

 

 

Dimensions

INDOOR UNIT

AS18A9(0)RCF/AS18A9(0)RCFD

AS24A1(2)RC/AS24A1(2)RCD

& Weight

 

 

 

 

W x H x D

inch(mm)

42 12 x 11 x 8

42 12 x 11 x 8

 

 

(1080 x 275 x 204)

(1080 x 275 x 204)

 

 

 

 

 

 

 

 

 

Net Weight

Ibs(kg)

29.7(13.4)

29.7(13.4)

 

 

 

 

 

 

OUTDOOR UNIT

US18A9(0)RCF/US18A9(0)RCFD

US24A1(2)RC/US24A1(2)RCD

 

 

 

 

 

 

W x H x D

inch(mm)

31 x 2483 x 12 58

3485 x 2581 x 12 14

 

(787 x 620 x 320)

(880 x 638 x 310)

 

 

 

 

 

 

 

 

 

Net Weight

Ibs(kg)

98.1(44)

138.9(62)

 

 

 

 

 