TROUBLESHOOTING
SYMPTOM: | Unit will not turn on. |
Problem: | Not plugged in. |
Solution: | Plug machine in proper outlet. |
Problem: | Circuit breaker has popped. |
Solution: | Reset circuit breaker. Make sure no other items are running on the |
| same circuit as machine. Outlet must be a |
Problem: | Power cord has become disconnected from extension cord. |
Solution: | Reattach power cord to extension cord. |
SYMPTOM: | Pump is not running properly. |
Problem: | Power cord and extension cord are not completely locked together. |
Solution: | Snap firmly together. |
Problem: | Jets on wand are clogged. |
Solution: | Clean jet with soft wire brush or remove jet and flush clean. |
Problem: | The solution tank is empty. |
Solution: | Fill the solution tank up with a |
Problem: | Pump is pulsating. |
Solution: | Tighten all hoses. Check for leaks. |
SYMPTOM: | Vacuum motor not working properly. |
Problem: | Hose not connected tightly to wand or machine. |
Solution: | Connect hose tightly. |
Problem: | Hose is clogged with hair, carpet fibers and/or debris. |
Solution: | Clean hose. |
Problem: | Drain plug is not shut completely. |
Solution: | Close drain plug completely. |
Problem: | Vacuum tank lid is not on tightly. |
Solution: | Secure the vacuum tank lid on tightly. |
Problem: | Vacuum tank lid is cracked. |
Solution: | Replace the vacuum tank lid. |
Problem: | Vacuum hose is cracked or split. |
Solution: | Replace vacuum hose. |
Problem: | Water is coming out of the vacuum motor. |
Solution: | Use a low foaming detergent. |
10