Dimensions

Features

 

 

Controls

 

Microprocessor

Remote Controller

LCD Wireless Type, Temp. Sensor Built In

Temperature Control

 

IC Thermostat

Timer

 

24 Hr Program; 1HR ON/OFF

Night Setback

 

Built-In

Air Louver

(Horizontal)

Manual

 

(Vertical)

Automatic

Power Failure Automatic Restart

Built-In

Self-Diagnosis

 

Built-In

Air Filter

 

Washable, Anti-Mold

Air Clean Apatite Filter

 

Standard

Quiet Operation

 

Built-In

Ion Generator

 

Built-In

Options

 

 

 

Refrigerant Line Set

 

Available

Fresh Air Intake

 

Knock-out

Airduct Extension

 

N/A

Condensate Drain Pump

 

Standard

Hard Wired Remote Controller

 

Available

Non-Removeable Locking Remo-con Bracket

Available

Operating Range

 

 

 

 

Indoor Air Intake Temp.

Outdoor Air Intake Temp.

Cooling

Maximum

95F DB/71F WB

115F DB

 

Minimum

67F DB/57F WB

0F DB

1Air intake

2Discharge outlet

3Refrigerant tubing (liquid tube) dia. 1/4" (flared)

4Refrigerant tubing (gas tube) dia. 1/2" (flared)

5Drain tube connection port VP20 (outer dia. 1")

6Power supply port

7Suspension bolt hole (4 - 1/2" x 1-1/8" hole)

8Fresh air intake duct connection port (dia. 3-7/8")

22-5/8 (575)

7 7/8-12

A

23-5/8 (600)

Ceiling opening dimensions

21-1/32 (534) Suspension bolt pitch

panel

(534) bolt

(600) dimensions

Center of

pitch

 

7/16-12 Suspension

openingCeiling

 

 

21-1/32

23-5/8

22-5/8 (575)

 

 

2-3/32 6-5/16 6-11/16

5

 

4-29/32

A View

 

21-3/16

3-19/32

 

 

7-11/16

10-13/16

15/32

 

 

-ID:15/16

 

 

ID:23/32

 

 

 

 

 

 

19/32-3

4

13/32-11

7/16-12

8

(265)7/16-10

 

 

 

 

 

3-5/8

 

Less than 31/32

 

2-3/32

7-23/32

2-3/4 1-9/32 5-9/16

1-27/32

1-3/32

4-19/32 1-25/32 1-25/32

Less than 31/32

2

25/32

2

1

2

 

8-15/32

11-5/32 (283)

6

3

1-3/16 (30)

24-19/32 (625)

2

14-3/32 (358)

 

13-5/32 (334)

24-19/32 (625)

The length of the suspension bolts should be selected so that there is a gap of 1-3/16" or the ceiling (21/32" or more below the lower surface of the main unit), as shown in the figure at right. If the suspension bolts is too long, it will contact the ceiling panel and the unit cannot be installed.

3-1/821/32 1-3/16

28-11/32 (720)

2-1/8

21-9/16 (548)

5/8

Wide tube service valve dia.3/8" (9.52)

Narrow tube service valve dia.1/4" (6.35)

4-9/32 2-5/32