SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
AIRCONDITIONING PRODUCTS
18KHS22
KHS1822/CH1822
WALL MOUNTED HEAT PUMP | |
|
|
GENERAL DATA (AT 230V)
POWER | V/PH/HZ |
|
|
|
| ||||
Circuit Ampacity, Min. (A) |
| 30 |
|
|
|
| |||
Fuse size, Max. | (A) |
| 30 |
|
|
|
| ||
|
|
|
|
|
| ||||
COMPRESSOR |
|
|
|
| |||||
No. used |
|
|
|
| 1 |
|
|
|
|
R.L. Amps - L.R. Amps (A) |
| 7.1 - 52.0 |
|
| |||||
Crankcase Heater | (W) |
| 30 |
|
|
|
| ||
|
|
|
|
| |||||
OUTDOOR FAN - TYPE |
| Propeller |
|
| |||||
Dia. (in.) - No. used |
|
| 15 3/4 - 1 |
|
| ||||
Type Drive - No. speeds |
| Direct - 2 |
|
| |||||
No. Poles - RPM (High) |
| 6 - 1,020 |
|
| |||||
No. Motors - HP |
|
| 1 - 1/12 |
|
|
| |||
CFM (High) |
|
|
| 1,190 |
|
|
|
| |
F.L. Amps. (A) |
|
|
| 0.5 |
|
|
|
| |
|
|
| |||||||
OUTDOOR COIL – TYPE |
| Aluminum Fin & Copper Pipe | |||||||
Fin Type - Pipe Type |
| Slit Plate - Inner Riffled | |||||||
Rows - F.P.I. |
|
|
| 2 - 15.9 |
|
|
| ||
Face Area | (sq.ft.) |
|
| 5.34 |
|
|
|
| |
Tube Size | (in.) |
|
| 3/8 |
|
|
|
| |
|
|
|
|
| |||||
INDOOR FAN - TYPE |
| Cross - Flow |
|
| |||||
Dia. & Length (in.) - No. used | 4 & |
|
|
| |||||
No. speeds |
|
|
| 3 & Auto |
|
|
| ||
No. Poles |
|
|
|
| |||||
No. Motors - HP |
|
| 1 - 1/75 |
|
|
| |||
CFM (HI/MED/LOW) |
| 440/380/320 |
|
| |||||
F.L. Amps (A) |
|
|
| 0.4 |
|
|
|
| |
|
|
| |||||||
INDOOR COIL – TYPE |
| Aluminum Fin & Copper Pipe | |||||||
Fin Type - Pipe type |
|
| Slit Plate - Inner Riffled | ||||||
Rows - F.P.I. |
|
|
| 2 - 14.1 |
|
|
| ||
Face Area | (sq. ft.) |
|
| 2.08 |
|
|
|
| |
Tube Size | (in.) |
|
| 3/8 |
|
|
|
| |
Drain Connection Size (in.) |
| 1 - 1/4 |
|
|
| ||||
|
|
|
|
|
|
|
| ||
REFRIGERANT |
|
| R22 |
|
|
|
| ||
Lbs. - R22 | (O.D. Unit) |
| 4.25 |
|
|
|
| ||
Control |
|
|
|
| Capillary Tube |
|
| ||
Connection |
|
|
| Flare |
|
|
|
| |
Line Length, Max (ft.) |
| 65 |
|
|
|
| |||
Lift difference, Max | (ft.) |
| 23 |
|
|
|
| ||
Line Size - in. O.D. Discharge | 1/4 |
|
|
|
| ||||
Line Size - in. O.D. Suction |
| 5/8 |
|
|
|
| |||
|
|
|
|
|
|
|
| ||
DIMENSIONS (in.) |
|
| H | x | W | x | D | ||
Indoor Unit | 14- 3/16 | x | 39 | x | |||||
|
| 18 |
| x | x | ||||
Outdoor unit | x | x | |||||||
|
| 28- | 3/32 | x | 39- 5/32 | x 16- 9/32 | |||
|
|
|
|
|
|
| |||
WEIGHT |
|
|
| INDOOR |
| OUTDOOR | |||
Net | (lbs.) |
| 29.8 |
| 134.5 |
|
| ||
Shipping | (lbs.) |
| 37.5 |
| 143.3 |
|
| ||
|
|
|
|
|
| ||||
Shipping Volume | (cu.ft.) | 4.8 |
| 10.3 |
| ||||
|
|
|
|
|
|
|
|
|
|
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)
COOLING |
|
|
|
|
|
| ||
Total Capacity | (BTU/H) | 16,500/16,000 |
| |||||
Sensible Capacity (BTU/H) | 10,390/10,060 |
| ||||||
Latent Capacity (BTU/H) | 6,110/5,940 |
|
| |||||
SEER |
|
|
| 10.0/10.0 |
|
| ||
Dehumidification(Pints/H) | 5.3/5.2 |
|
| |||||
Amps | (A) |
|
| 8.0/8.6 |
|
| ||
Power Inputs | (W) |
| 1,810/1,760 |
|
| |||
HEATING |
|
|
|
|
|
| ||
Total Capacity | (BTU/H) | 18,000/17,600 |
| |||||
HSPF |
|
|
| 6.8/6.8 |
|
| ||
Amps | (A) |
|
| 8.0/8.6 |
|
| ||
Power Inputs | (W) |
| 1,810/1,760 |
|
| |||
(KW) | 1.80/1.47 |
|
| |||||
Outdoor Sound Rating (bels) | 7.8 |
|
|
| ||||
FEATURE |
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
Controls |
|
|
| Microprocessor |
| |||
Remote Controller |
| LCD Wireless type |
| |||||
Temperature Control |
| IC Thermostat |
| |||||
Timer |
|
|
| ON/OFF, 24 hours |
| |||
Night Setback |
|
|
|
| ||||
Air Louve (Horizontal) | Manual |
|
| |||||
|
| (Vertical) |
| Automatic |
|
| ||
Power Failure Automatic Restart |
|
| ||||||
Self Diagnosis |
|
|
|
| ||||
Heating/Cooling Automatic Changeover |
|
| ||||||
OPTION |
|
|
|
|
|
| ||
|
|
|
|
|
| |||
Refrigerant Line Set |
| AP2507BH | (20 ft) |
| ||||
|
|
|
|
| AP2510BH | (30 ft) |
| |
|
|
|
|
| AP2515BH | (50 ft) |
| |
Low Ambient Control |
| N/A |
|
|
| |||
Fresh Air Intake |
| N/A |
|
|
| |||
Central Remote | Available |
|
| |||||
Airduct Extension |
| N/A |
|
|
| |||
Indoor Frame Extension | PLB 182 |
|
| |||||
Condensate Drain Pump | Available |
|
| |||||
Available |
|
| ||||||
OPERATING RANGE |
|
|
|
|
| |||
|
|
|
|
|
|
| ||
Cooling |
|
| Indoor Air | Outdoor Air |
| |||
|
|
|
| Intake Temp. | Intake Temp. |
| ||
|
| Maximum | 95 F DB/71 F WB | 115 F DB |
| |||
|
| Minimum | 67 F DB/57 F WB | 67 F DB |
| |||
Heating | Maximum | 80 F DB/67 F WB | 75 F DB / 65 F WB |
| ||||
|
| Minimum | - F DB/ - F WB | 17 F DB/ 15 F WB |
|
18KHS22