Sanyo 8.53E+13 installation instructions Installation Site Selection

Models: 8.53E+13

1 24
Download 24 pages 63.85 Kb
Page 4
Image 4
2. Installation Site Selection

05-423 KHS0971-1271 12/13/05 1:23 PM Page 4

1-5. Additional Materials Required for Installation

1.Refrigeration (armored) tape

2.Insulated staples or clamps for connecting wire (See local codes)

3.Putty

4.Refrigeration lubricant

5.Clamps or saddles to secure refrigerant tubing

2. Installation Site Selection

Indoor unit

Manual background Drain hose

Outside drainage

2-1. Indoor Unit

WARNING

AVOID:

direct sunlight.

To prevent abnormal heat genera- tion and the possibility of fire, do not place obstacles, enclosures and grilles in front of or surround- ing the air conditioner in a way that may block air flow.

Fig. 1

 

6" (15 cm)

2" (5 cm)

2" (5 cm)

min.

 

min.

min.

 

 

 

 

Front View

 

nearby heat sources that may affect performance of the unit.

areas where leakage of flammable gas may be expected.

places where large amounts of oil mist exist.

 

Fig. 2

 

 

Tubing length (L)

INDOOR

 

UNIT

 

 

 

 

 

DO:

select an appropriate position from which every corner of the room can be uniformly cooled. (High on a wall is best.)

select a location that will hold the weight of the unit.

Elevation difference (H)

OUTDOOR UNIT

select a location where tubing and drain hose have the

shortest run to the outside. (Fig. 1)

Fig. 3a

allow room for operation and maintenance as well as unre-

stricted air flow around the unit. (Fig. 2)

install the unit within the maximum elevation difference (H)

above or below the outdoor unit and within a total tubing length

(L) from the outdoor unit as detailed in Table 3 and Fig. 3a.

Install the indoor unit more than 3.3' (1 m) away from any

antenna or power lines or connecting wires used for television,

radio, telephone, security system, or intercom. Electrical noise

from any of these sources may affect operation.

CAUTION

For stable operation of the air conditioner, do not install wall-mounted type indoor units less than 5' (1.5 m) from floor level.

Indoor unit

Wall

Minimum height from floor level

5' (1.5 m)

Table 3

Floor level

Fig. 3b

 

Max. Allowable Tubing

Limit of Tubing

Limit of Elevation

Required Amount of

Model

Length at Shipment

Length (L)

Difference (H)

Additional Refrigerant

 

(ft.)

(ft.)

(ft.)

(oz./ft.)*

 

 

 

 

 

KHS0971

25

50

23

0.16

 

 

 

 

 

KHS1271

25

65

23

0.16

 

 

 

 

 

*If total tubing length becomes 25 ft. (max.), charge additional refrigerant (R410A) by 0.16 oz./ft. No additional charge of compressor oil is necessary.

4

Page 4
Image 4
Sanyo 8.53E+13 installation instructions Installation Site Selection