GB

RS232C COMMAND TABLES GB

Time Read Command Table

Status read command

Item

 

 

CR PANELH

Status of accumulated lifetime of panel..

(The same as CR_LAMPH Command)

 

 

 

CR MONH

Status of accumulated lifetime of monitor..

(The same as CR_PROJH Command)

 

 

 

Sound control Read Command Table

Status read command

Item

 

 

CR VOLUME

Status of volume value..

 

 

CR MUTE

Status of MUTE..

 

 

Setting Read Command Table

Status read command

Item

 

 

CR LANG

Status of Language selection..

 

 

CR P-MANE

Status of Power management setting..

 

 

CR TILE

Status of Tile mode ON/OFF setting..

 

 

CR TILE-HSETS

Status of Tile mode, the number of

Horizontal array..

 

 

 

CR TILE-VSETS

Status of Tile mode, the number of

Vertical array..

 

 

 

CR TILE-HLOCAT

Status of Tile mode, the number of

Horizontal allocation..

 

 

 

CR TILE-VLOCAT

Status of Tile mode the number of Verti-

cal allocation..

 

 

 

CR TILE-BZLHADJ

Status of Tile mode, the width of bezel

(Horizontal)..

 

 

 

CR TILE-BZLVADJ

Status of Tile mode, the width of bezel

(Vertical)..

 

 

 

CR ONPROG

Status of On Program information..

 

 

CR WINTERMODE

Status of Winter mode Information..

 

 

CR PANELPROTECT

Statuses of Panel protect Information..

 

 

CR LEDLIGHT

Status of LED light Information..

 

 

CR AVAUTOSHUT

Status of AV auto shut OFF Information..

 

 

CR CHILDLOCK

Statuses of Child lock Information.

 

 

CR RCINHIBITION

Status of RC Inhibit Information..

 

 

Other Read Command Table

Status read command

Item

 

 

CR STATUS

Status of the operation of the monitor..

 

 

CR SIGNAL

Status of with or without signal..

 

 

CR FREEZE

Status of Freeze setting..

 

 

CR FANLOCK

Statuses of fan lock error.

 

 

CR TEMP

Status of current temperature value..

 

 

UK5 Read Command Table (Basic Command)

Command

Item

Note

 

 

 

CR0

Power

On, Standby, power error,

 

 

 

CR1

Input Mode

AV1, AV2, .. .. .. , DVI, PC

 

 

 

CR WIDE

Wide mode

Auto, Normal, Full,

 

 

 

CR PICTURE

Picture mode

Dynamic, Standard,

 

 

 

CR SIGNAL

Signal existence

Signal/No signal

 

 

 

CR CHILD

Child lock

On/Off

 

 

 

CR PSAVE

Power save

On/Off

 

 

 

CRTM

Panel usage time

–––

 

 

 

CR RMC

RC inhibition

On/Off

 

 

 

CR MDL

Model number

Model number

 

 

 

Error code Table

Error code

Note

• Receiving the data that cannot be decoded..

?• The wrong indication of parameter..

(Wrong figured number, or wrong word is included)

000

Normal receiving.. (no error)

102If the command of out of range is directly entered valuable parameter..

No matching with Hardware..

103(Command for optional function which is not equipped)

201If the command of “Out of range” is entered by inclement or decrements by numeric value..

301While capturing the picture, no execution.. Wait and transmit command again..

402While PIN code is in operation, no execution.. Wait and transmit command again..

101

The errors not including above..

21

Page 21
Image 21
Sanyo PID-42AE1, PID-42AS1 instruction manual RS232C Command Tables GB

PID-42AE1, PID-42AS1 specifications

The Sanyo PID-42AS1 and PID-42AE1 represent a significant advance in the world of air conditioning technology. Designed to offer exceptional performance, energy efficiency, and user comfort, these models are ideal for both residential and commercial applications.

Both models feature Sanyo's advanced inverter technology, which allows for precise temperature control and energy savings. By adjusting the compressor speed according to the current cooling needs, these units maintain a consistent temperature while reducing energy consumption. Inverter technology not only enhances efficiency but also minimizes noise levels, making these units suitable for quiet environments such as bedrooms and offices.

The PID-42AS1 is recognized for its superior cooling capacity. It features a powerful compressor that delivers rapid cooling, thus ensuring a comfortable indoor environment even during the hottest days. The unit also includes a high-efficiency air filter, which captures dust and allergens, promoting cleaner air circulation throughout the space.

On the other hand, the PID-42AE1 is designed with an eco-friendly approach. It utilizes R410A refrigerant, which has a lower impact on the environment compared to traditional refrigerants. Additionally, this model is equipped with energy-saving modes that allow users to optimize the cooling performance based on their needs, further enhancing its sustainability profile.

Both models boast an intuitive remote control that simplifies operation. With features like programmable timers and multiple cooling modes, users can easily customize their experience. The sleek design of these units allows them to blend seamlessly into any interior space, while the compact dimensions make them easy to install.

In summary, the Sanyo PID-42AS1 and PID-42AE1 offer a blend of innovative technology and user-friendly features. The inverter technology provides energy efficiency and noise reduction, while the advanced cooling capabilities ensure comfort. With eco-friendly refrigerant and filters that improve air quality, these models are at the forefront of modern air conditioning solutions. Whether for home or office use, Sanyo's commitment to quality and innovation is evident in every aspect of these air conditioning units.