SPECIFICATIONS

Scanning system

: VCC-5995P:PAL standard 625 lines, 50 fields/sec.

 

 

VCC-5884EA:NTSC standard 525 lines, 60 fields/sec.

Image sensor

: 1/3" interline transfer method CCD

Number of effective pixels

:

752 (H) x 582 (V)

Horizontal resolution

:

540 TV lines, typical

Minimum illumination

:

0.5 lx (F1.2, AGC ON)

Video output

:

1.0 V(p-p)/75 , composite, BNC

Video S/N ratio

: More than 48 dB (AGC OFF: More than 50 dB)

Light control

: Optical auto iris lens (DC type)/Electronic iris (indoor use)

Lens mount

: CS mount

INSTRUCTION MANUAL

Color CCD Camera

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL CODES.

About this manual

VCC-5995P VCC-5884EA

Flange back

: 12.5 mm ±0.5 mm/0.5 in. ±0.02 in.

Backlight compensation

: ON (Center zone metering)/OFF

Gain control

: AGC ON/OFF

Sync system

: Internal sync/Line lock

Operating Environment

: Temperature: -10°C – +50°C (14°F – 122°F)

 

Humidity: less than 90 % RH (no condensation)

Power supply

: VCC-5995P:24 V AC ±10%, 50 Hz/ 12 – 15 V DC

 

VCC-5884EA:24 V AC ±10%, 60 Hz/ 12 – 15 V DC

Power consumption

: Approx. 3.6 W (with auto-iris lens)

Weight

: Approx. 160 g/5.6 oz. (without lens)

Before installing and using the camera, please read this manual carefully. Be sure to keep it handy for later reference.

This manual covers two models. Any difference between the two models is indicated when necessary.

ATTACHING THE LENS

To prevent damaging the camera
Dimensions

Unit: mm (inch)

63(2.5)51(2.0)

1(0.04) 49(1.9)

68(2.7)

Service

The camera is a precision instrument. Handle it carefully and always follow the safety precautions. If the camera requires service, never try to repair it yourself or open the casing.

For servicing, maintenance, or repairs, consult your dealer or an Authorized Sanyo Service Center.

LENS terminal for auto iris lens

Brake coil (–)

Drive coil (+)

Brake coil (+) Drive coil (–)

5 mm/0.2 in. max.

Apply adapter ring (sold separately) when you use any

C mount lens.

Depending on the type of the lens, the shape of the lens plug may differ. In this case, consult your dealer or an Authorized Sanyo Service Center.

PRECAUTIONS

Appearance and specifications are subject to change without prior notice or obligations.

1, 4

Flange-back adjustment

1)

Loosen the two screws.

 

2

2)

Set to the maximum telephoto position and focus the picture.

3)

Set to the maximum wide-angle position and focus the picture.

 

 

• When the lens barrel is turned, the CS mount ring also turns causing

 

 

it to act as the flange-back adjustment dial.

 

Repeat steps 2 and 3 until the image stays in-focus when changing from a

 

wide-angle position to a telephoto position.

3

4)

Tighten the two screws.

If the flange-back lock screws are loose, the CS mount ring will not be secured and it will not be possible to adjust the flange-back.

Remove the lens and check that the two flange-back lock screws have been tightened, then fully install the lens again.

SANYO Electric Co., Ltd.
In case of a problem

Do not use the unit if smoke or a strange odor comes from the unit, or if it seems not to function correctly. Turn off the power immediately and disconnect the power cord, and then consult your dealer or an Authorized Sanyo Service Center.

Do not open or modify

Do not open the cabinet, as it may be dangerous and cause damage to the unit. For repairs, consult your dealer or an Authorized Sanyo Service Center.

Do not put objects inside the unit

Make sure that no metal objects or flammable substance get inside the unit. If used with a foreign object inside, it could cause a fire, a short-circuit or damage. Be careful to protect the unit from rain, sea water, etc. If water or liquid gets inside the unit, turn off the power immediately and disconnect the power cord, and then consult your dealer or an Authorized Sanyo Service Center.

Be careful when handling the unit

To prevent damage, do not drop the unit or subject it to strong shock or vibration.

Do not install this unit close to magnetic fields The magnetic fields may result in unstable operation.

Protect from humidity and dust

To prevent damage, do not install the unit where there is greasy smoke or steam, where the humidity may get too high, or where there is a lot of dust.

Protect from high temperatures

Do not install close to stoves, or other heat sources, such as spotlights, etc., or where it could be subject to direct sunlight, as this could cause deformation, discoloration or other damage.

Be careful when installing close to the ceiling, in a kitchen or boiler room, as the temperature may rise to high levels.

Cleaning

Dirt can be removed from the cabinet by wiping it with a soft cloth. To remove stains, wipe with a soft cloth moistened with a soft detergent solution and wrung dry, then dry by wiping with a soft cloth.

Do not use benzine, thinner or other chemical products on the cabinet, as this may cause deformation and paint peeling. Before using a chemical cloth, make sure to read all accompanying instructions. Make sure that no plastic or rubber material comes into contact with the cabinet for a long period of time, as this may cause damage or paint peeling.

1AC6P1P3343--

 

L5CR2/XE, US (0808KP-HS)