
INFORMATION TO USER
PRECAUTIONS
INSTRUCTION MANUAL |
|
(Warranty attached)
COLOR CCD cameraAbout this manualBefore installing and using the camera, please read this manual carefully. Be sure to keep it handy for later reference.
Dimensions: mm
109 |
| 56 |
|
|
|
0.5100
45
11
Safety Guard
THIS SYMBOL INDICATES THAT THERE ARE IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THIS UNIT.
WARNING:TO PREVENT THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
For the customers in CanadaThis Class B digital apparatus complies with Canadian
Cet appareil numerique de la Classe B est conforme a la norme
This installation should be made by a qualified service person and should conform to all local codes.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
In case of problem
Do not use the camera if smoke or strange odors come from the unit, or if it seems not to function correctly. Disconnect the power cord immediately, and consult your dealer or a Sanyo Authorized Service Center.
Do not open or modify
Do not open the cabinet, as it may be dangerous and cause damage to the unit. For internal settings and repairs, consult your dealer or a Sanyo Authorized Service Center.
Do not put objects inside the unit
Make sure that no metal objects or flammable substances get inside the camera. If used with a foreign object inside, it could cause fire,
Be careful when handling the unit
To prevent damage, do not drop the camera or subject it to strong shock or vibration.
Install away from electric or magnetic fields
Protect from high temperatures
Do not install close to stoves, or other heat generating devices, such as spotlights, or where it could be subject to direct sunlight, as that could cause deformation, discoloration or other damage.
Be careful when installing close to the ceiling, in a kitchen or boiler room, as the temperature may rise to high levels. Install where the temperature range will stay between
Cleaning
Dirt can be removed from the cabinet by wiping it with a soft cloth. To remove stains, use a soft cloth moistened with a soft detergent solution and wrung dry, then dry by wiping with a soft dry cloth.
Do not use benzine, thinner or other chemical products on the cabinet, as they may cause deformation and paint peeling. Before using a chemical cloth, make sure to read all accompanying instructions. Make sure that no plastic or rubber material comes in contact with the cabinet for extended periods, as that may cause damage or paint peeling.
12 | 28 |
|
|
22
AccessoriesLens iris plug
Depending on the conditions of use, installation and environment, please be sure to make the appropriate settings and adjustments. If you need help with installation and/or settings, please consult your dealer.
on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by Sanyo may void the user's authority to operate this camera.
If installed close to a TV, radio transmitter, magnet, electric motor, transformer, or audio speakers, the magnetic field they generate will distort the image.
Protect from humidity and dust
To prevent damage to the camera, do not install it where there is | Printed on recycled paper |
|
greasy smoke or steam, where humidity may get too high, or where |
| |
|
| |
there is a lot of dust. |
| |
SANYO Electric Co., Ltd. | ||
| L53X4/US3 | Printed in Japan |
NAMES AND FUNCTIONS OF PARTS
TROUBLESHOOTING
SPECIFICATIONS
Connects to the VIDEO IN (video input) terminal on the VCR or monitor.

When using two cameras or more, the image on the monitor may roll vertically when switching sources. This rolling can be minimized by turning this volume.

Lights when the camera power is ON.
GND, AC24V, DC12V (ground terminal, 24V AC or 12V DC input terminal)
Protects the lens from damage.

Contains camera adjustment dials and setting switches.
Attaching the lens
Use a DC type
Do not use a lens if length “L” is more than 5 mm. Otherwise, it may damage the camera and prevent proper installation.
When attaching a C mount lens, attach the lens to the camera after inserting the C mount ring (option).
1 | Remove the lens mount | L | |
2 | |||
2 | cap from the camera. | ||
Install the |
| ||
3 | Connect the lens plug to 3 | 1 | |
| the lens iris output |
| |
| connector (LENS) on the | CS mount type lens | |
| side of the camera. |
When using lenses from other manufacturers, the plug shape may not correspond to the terminal on the camera. In such a case, remove the original plug and using a soldering iron, connect the supplied lens iris plug according to the diagram.
Before sending the camera out for repair, check the items below. If the problem persists after checking these items, contact your place of purchase or a Sanyo Authorized Service Center.
If no image appears
Is the coaxial cable attached securely? Are the power and voltage normal?
Has the iris of the lens inside the camera been adjusted correctly (with the iris dial)?
Is there adequate illumination?
If the image is unclear
Is the monitor adjusted correctly?
Is the
Is the lens dirty?
Dirt or fingerprints on the lens can adversely affect the image. Gently wipe any dirt or fingerprints off the lens with a soft cloth or lens cleaning paper and cleaning fluid (commercially available).
SERVICE
Scanning system | : NTSC standard TV system |
| (525 TV lines, 30 frames/sec.) |
Interlace | : PLL 2:1 interlace |
Image device | : 1/3 inch solid state image device CCD |
Picture elements | : 816 (H) x 494 (V) |
Effective picture | : 771 (H) x 492 (V) |
elements |
|
Synchronizing system : Internal sync, Line lock manually switchable | |
Resolution | : 520 TV lines horizontally, 350 TV lines vertically |
Video output level | : 1.0 |
Video S/N ratio | : More than 48 dB |
Minimum required | : Approx. 0.6 lux with a F 1.2 lens (at Gain up: HI) |
illumination | Approx. 1.2 lux with a F 1.2 lens (at Gain up: NORM) |
(incandescent lighting) |
|
Backlight | : Manual MULT/CENT/OFF switching, |
compensation | MULT: |
| CENT: |
| (Active when using an |
Iris function | : Manual EI/AI switching |
: DC output (variable DC level), | |
Electronic iris range | : 0.6 lux to 30000 lux (F 1.2, lens: Gain up: HI) |
| 1.2 lux to 60000 lux (F 1.2, lens: Gain up: NORM) |
: 12.5 mm ±0.5 mm | |
White balance | : ATW/Manual switching |
Gain up | : HI (high)/ NORM (Normal) switching |
Lens mount | : CS mount |

Used to attach the camera.


Used to connect the lens plug when the lens is attached.
c Brake coil | d Brake coil (+) |
e Drive coil (+) | f Drive coil |
Rewiring the lens cable in the lens iris plug
1Prepare the lens cable.Cut the cable at the plug, then remove approx. 8 mm of | 2mm | |
the cable sheath and strip about 2 mm from each wire. | ||
|
Solder the cable to the pins following the correct pin layout (), then close the plug cover.
The camera is a precision instrument. Handle it carefully and always follow the safety precautions. If the camera requires service, never try to repair it yourself or open the casing.
For servicing, maintenance, or repairs, contact your place of purchase or a Sanyo Authorized Service Center.
Environmental | : Temperature: |
conditions | Humidity: less than 90% (no condensation) |
Power supply | : 12 VDC/24 VAC, 60 Hz |
Power consumption | : 3.6 W (with auto iris lens) |
Weight | : Approx. 310 g (without lens) |
Features and specifications are subject to change without prior notice or obligations.