3. SERVICE ADJUSTMENTS

1. Supply power to the set and measuring instruments and allow to warm up for at least 30 minutes.

NOTE

Be sure to use a non-metallic driver for adjusting there VRs. A metallic driver can cause damage by shorting.

Adjustment tool

1.Digital multi meter

2.Pattern generator

3.Color analyzer

Adjustment mode

Over scan mode

ADJUSTMENT

TIMING

SETTING

VR

ADJUSTMENT PROCEDURE

ITEM

PATTERN

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

CHECK B+

PATTERN GENERATOR

 

 

TEST POINT : D910(-)

VOLTAGE

MONOSCOPE PATTERN

 

 

DIGITAL VOLT METER

 

 

 

 

VALUE 46.0 ± 0.5 VDC.

 

 

 

 

 

HOLD DOWN

PATTERN GENERATOR

BRIGHT VR ,

VR503

TEST POINT : ZD501(-)

VOLTAGE

MONOSCOPE PATTERN

CONTRAST VR

 

DIGITAL VOLT METER

SETTING

 

and SHARP-

 

VALUE 8.5 ± 0.2 VDC.

 

 

NESS VR TO

 

 

 

 

MAX.

 

 

 

 

 

 

 

FOCUS

PATTERN GENERATOR

BRIGHT VR ,

FBT FOCUS

Adjusting FBT FOCUS VR to make

ADJUSTMENT

MONOSCOPE PATTERN

CONTRAST VR

VR

csreen corner & center focus be identical.

 

 

and SHARP-

 

 

 

 

NESS VR TO

 

 

 

 

MAX.

 

 

 

 

 

 

 

HORIZONTAL

PATTERN GENERATOR

BRIGHT VR ,

VR401

Adjusting VR401 horizontal phase to

PHASE

MONOSCOPE PATTERN

CONTRAST VR

 

make screen right and left symmetrize.

ADJUSTMENT

 

and SHARP-

 

 

 

 

NESS VR TO

 

 

 

 

MAX.

 

 

 

 

 

 

 

VERTICAL

PATTERN GENERATOR

BRIGHT VR ,

VR302

Adjusting vertical linear control VR302 for

LINEARY

MONOSCOPE PATTERN

CONTRAST VR

 

equal spacing of lines between center

ADJUSTMENT

 

and SHARP-

 

extreme of scan.

 

 

NESS VR TO

 

 

 

 

MAX.

 

 

 

 

 

 

 

PINCUSHION

PATTERN GENERATOR

BRIGHT VR ,

VR304

Adjusting VR304 to make pincushion

ADJUSTMAN

CROSS HATCH PATTERN

CONTRAST VR

 

distortion be identical.

 

 

and SHARP-

 

 

 

 

NESS VR TO

 

 

 

 

MAX.

 

 

 

 

 

 

 

VERTICAL

PATTERN GENERATOR

BRIGHT VR ,

VR303

Adjusting VR303 to make screen up &

CENTER

MONOSCOPE PATTERN

CONTRAST VR

 

down symmetrize.

ADJUSTMENT

 

and SHARP-

 

 

 

 

NESS VR TO

 

 

 

 

MAX.

 

 

 

 

 

 

 

VERTICAL

PATTERN GENERATOR

BRIGHT VR ,

VR301

Adjusting VR301 to make screen V-size

SIZE

MONOSCOPE PATTERN

CONTRAST VR

 

to level wide3/4.

ADJUSTMENT

 

and SHARP-

 

 

 

 

NESS VR TO

 

 

 

 

MAX.

 

 

 

 

 

 

 

– 7 –