Schumacher Electric Corporation

Model IP-1825FL

OWNER’S MANUAL

INSTANT POWER™ Jump Starter & DC Power Source

THIS PRODUCT HAS A SEALED LEAD-ACID BATTERY INSIDE THAT SHOULD BE KEPT AT FULL CHARGE FOR LONGER LIFE. RECHARGE WHEN FIRST RECEIVED (EVEN IF GREEN ‘FULL POWER’ LED GLOWS), AFTER EACH USE AND EVERY 3 MONTHS.

IMPORTANT SAFETY INSTRUCTIONS

Save these instructions

important safety instructions

Someone should be within range of your voice or close enough to come to your aid when you are working near a lead-acid battery.

Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. If acid enter the eye area, rinse with cold water for at least 10 minutes and get medical help immediately.

Do not smoke, or use matches or cigarette lighter, or allow any spark or flame near the battery or engine.

Never operate the power source unit if it has damaged lead wire or clamps. Have the lead wire replaced by a qualified technician.

Wear complete eye and clothing protection when working with lead-acid batteries.

Do not permit the internal battery in the IP-1825FL to freeze. Never attempt to recharge a frozen battery.

handling warning

WARNING: Handling the cord on this product or cords associated with this product, may expose you to lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

Operating Instructions

Warning: Failure to follow instructions may cause damage or an explosion. Read entire instruction manual before use.

1.Turn ignition OFF before making cable connections.

2.Use in a well-ventilated area.

3.Keep clear of fan blades, belts, pulleys and other parts that may cause injury.

4.NEVER allow clamps to touch together or to contact the same piece of metal to prevent sparking.

5.Clamp the red clamp (+) to the positive terminal (+) of the battery. (For a negative grounded system.)*

6.Clamp the black clamp (-) to an unpainted and unmoving part of the chassis or engine block.

7.You can now crank the engine. If the engine does not start within 3-8 seconds, wait at least 1 minute before attempting to start vehicle again. (This permits the battery to cool down.)

8.After the engine starts, first disconnect the black clamp (-) and then the red clamp (+) in that order. Store the clamps on the ears located on the sides of the case.

9.Recharge the IP-1825FL as soon as possible after use.

*NOTE: In the rare case of jump-starting a vehicle that has a positive-grounded vehicle electrical system, connect the NEGATIVE black clamp (-) to the negative terminal (-) of the vehicle battery. Then connect the POSITIVE red clamp (+)

to an unpainted and unmoving part of the vehicle chassis or engine block. If you are unsure of the nature of the vehicle’s electrical grounding system, check the owner’s manual of the vehicle. To disconnect clamps, reverse order.

LED INDICATORS

To check the internal battery’s charge status, press the red button on the front of IP-1825FL.

The LED lights will indicate the charge level as follows:

1.A red LED indicates a 50% or less charge and you should immediately recharge IP-1825FL.

2.A yellow LED indicates a 50 to 75% charge. IP-1825FL may be used but should be recharged as soon as possible.

3.A green LED indicates the internal battery is fully charged.

CHARGING of internal battery with built-in charger.

After removing the IP-1825FL from the carton, charge it for a minimum of 8 hours even if the green Full Power LED glows.

1.To charge, plug extension cord into charger plug on the side of the IP-1825FL. (Extension cord not included; must be purchased separately.)

2.Plug the extension cord into 110V AC electrical wall outlet.

3.The red LED will glow while charging.

4.The green LED will glow when the battery has reached full charge. This could take up to 72 hours on some charges due to age and condition of the battery. The charger will automatically drop into a float mode and maintain the battery at full charge without damaging the battery. The IP-1825FL can be left plugged into the 110V wall outlet indefinitely to maintain full power.

5.Recharge IP-1825FL after use and every 3 months to full charge status to extend the battery’s life.

multi-purpose power supply

The IP-1825FL is a power source for all 12 volt DC accessories that are equipped with a 12V accessory plug. Make sure the device to be powered is OFF before inserting 12 volt accessory plug into 12 volt accessory outlet on the IP-1825FL. Use the 12 volt accessory outlet for power outages, fishing and camping trips. Estimate usage time is listed in chart below.

12 Volt DC Power source Chart

Appliance Type

Estimated Wattage

Estimated Time*

Cell Phones

4 Watts

30 Hours

Fluorescent Lights

4 Watts

30 Hours

Radios

9 Watts

21 Hours

Depth Finders

9 Watts

21 Hours

Fans

9 Watts

21 Hours

00-99-000673/1106

Page 1
Image 1
Schumacher IP-1825FL owner manual Instant Power Jump Starter & DC Power Source, Important Safety Instructions

IP-1825FL specifications

The Schumacher IP-1825FL is a versatile and powerful jump starter and power bank designed to meet the needs of vehicle owners and outdoor enthusiasts alike. This innovative device combines advanced technology with user-friendly features, making it a reliable companion for anyone who requires a quick boost for their vehicle or a dependable power source for electronics on the go.

One of the standout features of the Schumacher IP-1825FL is its impressive peak current output of 1,800 amps. This ensures that it can jump-start most vehicles, including those with larger engines such as trucks and SUVs. The unit is equipped with heavy-duty, high-performance jumper cables that provide secure connections and reduce the risk of damage to vehicle batteries during the jump-start process.

In addition to its jump-start capabilities, the Schumacher IP-1825FL functions as a portable power bank, featuring multiple USB ports for charging a variety of devices. Whether it's smartphones, tablets, or other USB-powered gadgets, users can enjoy the convenience of charging on the move. This makes it ideal for camping trips, road adventures, and emergency situations.

The device is also designed with built-in LED lights that offer illumination when needed. These lights serve multiple purposes, from providing light in dark environments to functioning as a distress signal in emergency cases. The IP-1825FL is designed with safety in mind, featuring short-circuit, overcharge, and overheat protection to ensure safe operation during use.

The Schumacher IP-1825FL is built for durability and portability. Its compact design makes it easy to store in the trunk of a vehicle or carry along on outdoor excursions. The rugged casing is resistant to impact and weather elements, contributing to its longevity and reliability in various environments.

Overall, the Schumacher IP-1825FL is a comprehensive power solution that combines jump-starting capabilities with portable charging options. Its high peak current, safety features, integrated LED lights, and durable design make it an essential tool for both everyday drivers and outdoor adventurers. Whether facing a dead battery or needing to charge devices away from home, the Schumacher IP-1825FL stands out as a dependable choice.