2. The power input from the battery exceeds 15 volts.
3. The continuous load demand from the equipment or
appliance being operated exceeds 400 watts.
4. The case temperature exceeds 145 ºF.
Attention: The PI-400 is fitted with a cooling fan that
runs as needed while the inverter is operating. If the
cooling fan is unable to maintain a cool enough tempera-
ture for safe operation, the inverter will automatically shut
down. If the inverter automatically shuts down or a con-
tinuous audible alarm is heard:
1. Turn the inverter rocker switch to the OFF (O).
2. Determine the source of the problem, and resolve it
before continuing to use the inverter.
Important Safety Measures
For the most effective use, place the power inverter
on a flat surface.
Keep the inverter dry.
DO NOT allow it to come into contact with rain or
moisture.
DO NOT operate the inverter if you, the inverter, the
device being operated or any other surfaces that may
come in contact with any power source are wet. Water
and many other liquids can conduct electricity, which
may lead to serious injury or death.
Do not place the inverter on or near heating vents,
radiators or other sources of heat.
Do not place the inverter in direct sunlight. The ideal
air temperature for operation is between 50º and 80ºF.
Keep the inverter well ventilated in order to properly
disperse heat generated while it is in use.
-7-