8.Troubleshooting

PROBLEM

 

REASON

 

SOLUTION

 

 

 

 

 

The RED LED is lit,

 

Poor contact at

 

Unplug and reinsert

or inverter does not

 

terminals.

 

the 12-volt plug.

function.

 

Fuse Blown.

 

See “IF THE

 

 

 

 

 

 

 

INVERTER FUSE

 

 

 

 

BLOWS” section.

 

 

Inverter shutdown.

 

See “LED

 

 

 

 

INDICATOR AND

 

 

 

 

SHUTDOWN

 

 

 

 

PROTECTION”

 

 

 

 

section.

 

 

Inverter may not be

 

See Warranty

 

 

working properly.

 

and call

 

 

 

 

Customer Service

 

 

 

 

1-800-621-5485

 

 

 

 

(Hours: 7:00 am –

 

 

 

 

5:00 pm CST).

 

 

 

 

 

 

 

 

 

 

9. SPECIFICATIONS

 

 

 

Maximum Continuous Power

 

150 Watts

Surge Capability (Peak Power)

 

300 Watts

No Load Current Draw

 

 

<0.36A

Wave Form

 

Modified Sine Wave

Input Voltage Range

 

 

10.5V - 15.5V DC

Output Voltage Range

 

 

120V ± 10% AC

Low Battery Shutdown

 

 

10.5V ± .5V DC

High Battery Shutdown

 

 

15.0V - 16.0V DC

Optimum Efficiency

 

>90%

AC Outlet

One, 120V AC 3-Prong

USB Port

 

 

One

30" Cable with 12V Accesory Plug

 

One

• 6 •

Page 7
Image 7
Schumacher PIC-150-USB owner manual Problem Reason Solution, Specifications