How to Assemble Your AccuGreen® 1000™
Check to see if you have all parts shown below.
Do not completely tighten nuts until the spreader assembly is complete.
Parts List *Furnished in Hardware Kit
1.Handle Assembly
2.Micrometer Housing
3.Micrometer Barrel
4.Bolt, 4 ea.*
5.Frame Leg, 2 ea.
6. Thumbnut, 4 ea.*
1
7. Hopper Assembly
2
8.Wheel, 2 ea.
9.Axle Washer, 2 ea.*
10.Cotter Pin, 2 ea.*
11.Hubcap, 2 ea.
3
1Frame Legs
Insert frame legs (5) into the hopper assembly (7) slots.
Attach legs to hopper, inserting bolts (4) through hopper then leg. Fasten legs in place with thumbnuts (6) on outside of hopper.
Hopper Slot
2 Wheels
Slide wheels (8) onto axle with the hub facing out.
Slide axle washers (9) onto axle.
Slip cotter pins (10) through axle holes and bend the ends around the axle.
Align hubcaps (11) and snap into place.
How to Calibrate the Spreader
IT IS NECESSARY TO CALIBRATE YOUR SPREADER AFTER
ASSEMBLING IT OR IT MAY SPREAD THE INCORRECT AMOUNT
OF PRODUCT.
1 Set Micrometer | 6 centered in window |
Turn micrometer until 6 is centered in window. |
2Position Spreader
Stand the spreader on its handle with the
Scotts logo facing away from you.
Press gently with your foot on the control lever and observe the position of the shutoff bar.
4
5
6
7
3 Handle
Micrometer
Attach handle assembly (1) using bolts and Window thumbnuts. Micrometer window must face the
front of the spreader, thumbnuts face inside.
3Check Shutoff Bar
With your foot on the control lever, the front edge of the shutoff bar at bottom of hopper should line up with the calibration line engraved into the bottom of the hopper.
You may need to pull the shutoff bar towards you to see the calibration line.
Calibration line
Shutoff bar
8
9
10
4 Micrometer Wire
Screw micrometer barrel (3) into the micrometer housing (2).
Tighten handle assembly and all other nuts.
4 Adjust Calibration Screw | Calibration screw |
If the shutoff bar covers the calibration line, turn the adjustment screw
If the bar is below the line, turn the adjustment screw clockwise.
11