General DC power requirement notes.

1.Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current shown.

2.The +5V and +12V supplies should employ separate ground returns.

3.Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device.

4.Parameters, other than spindle start, are measured after a 10-minute warm up.

5.No terminator power.

6.2.1Conducted noise immunity

Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power connector.

+5V

=

250 mV pp from 100 Hz to 20 MHz.

+12V

=

800 mV pp from 100 Hz to 8 KHz.

 

 

450 mV pp from 8 KHz to 20 KHz.

 

 

250 mV pp from 20 KHz to 5 MHz.

6.2.2Power sequencing

The drive does not require power sequencing. The drive protects against inadvertent writing during power-up and down.

6.2.3Current profiles

The +12V and +5V current profiles are shown below in the following figures.

Note: All times and currents are typical. See Tables 3, 4, and 5 for maximum current requirements.

Figure 1. Typical 600GB current profiles

CHEETAH 15K.7 SAS PRODUCT MANUAL, REV. F

21

Page 26
Image 26
Seagate ST3300657SS, 100516226, ST3300457SS, ST3300557SS manual Conducted noise immunity, Power sequencing, Current profiles