2.10Environmental specifications

Note. The removable drive cartridge should be stored for less than 60 days when exposed to continuous maximum temperature and humidity conditions of 40°C (104°F) and 80% relative humidity. Exceed- ing this duration in these conditions may result in loss of data.

2.10.1Ambient temperature

Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 65°C (149°F) within the operating ambient conditions.

Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.

Operating

5° to 55°C (41° to 131°F)

 

 

Nonoperating

–40° to 70°C (–40° to 158°F)

 

 

System storage

0° to 30°C (0° to 86°F)

 

 

Drive cartridge storage

0° to 30°C (0° to 86°F)

 

 

2.10.2Temperature gradient

Operating

20°C per hour (68°F per hour max), without condensation

 

 

Nonoperating

30°C per hour (86°F per hour max), without condensation

 

 

2.10.3Humidity

Refer to the following two sections for relative humitidy and wet bulb temperature specifications.

2.10.3.1Relative humidity

Operating

5% to 90% noncondensing (30% per hour max)

 

 

Nonoperating

5% to 95% noncondensing (30% per hour max)

 

 

Drive cartridge storage

20% to 40% noncondensing (30% per hour max)

 

 

2.10.3.2Wet bulb temperature

Operating

30°C (86°F) max

 

 

Nonoperating

40°C (104°F) max

 

 

Drive cartridge storage

25°C (77°F) max

 

 

2.10.4

Altitude

 

 

 

 

 

Operating

–304.8 m to 3,048 m (–1,000 ft to 10,000+ ft)

 

 

 

 

Nonoperating

–304.8 m to 12,192 m (–1,000 ft to 40,000+ ft)

 

 

 