Seagate 5400-RPM Acoustics, Electromagnetic immunity, Drive A-weighted Sound Power Levels SWL, BA

Models: 5400-RPM 7200-RPM

1 44
Download 44 pages 36.1 Kb
Page 21
Image 21

3.11Acoustics

Drive emission of sound is measured consistent with the ECMA-74 and its referenced standards. Testing is conducted at room temperature (approximately 25°C). Emission levels are reported as the total A-weighted sound power levers for steady state, idle, and active seeks modes of operation.

Table 5: Drive A-weighted Sound Power Levels (SWL, BA)

Idle*

Performance seek

 

 

2.3 bels (typ)

2.6 bels (typ)

2.5 bels (max)

2.7 bels (max)

 

 

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.

Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this pro- cess is the use of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74 standards.

*Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.

3.12Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 6:

Radio frequency environments

 

 

 

 

 

 

 

 

 

 

Performance

Reference

Test

 

Description

level

standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

 

 

 

 

Radiated RF immunity

80 to 1,000 MHz, 3 V/m,

A

EN 61000-4-3: 96

 

 

80% AM with 1 kHz sine

 

ENV 50204: 95

 

 

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz

A

EN 61000-4-6: 97

 

 

sine

 

 

 

 

 

 

Power Frequency H-field

1 A/m, 50Hz/60Hz, 3 axes

A

EN 61000-4-8: 97

immunity

 

 

 

 

 

 

 

 

Voltage dips, interrupts

30% Reduction for 25 cycles

C

EN 61000-4-11: 94

 

 

>95% Reduction for 250 cycles

C

 

 

 

>95%, 0.5 cycles

B

 

 

 

 

 

 

Momentus Product Manual, Rev. B

15

Page 21
Image 21
Seagate 5400-RPM, 7200-RPM manual Acoustics, Electromagnetic immunity, Drive A-weighted Sound Power Levels SWL, BA