2.7ENVIRONMENTAL LIMITS

2.7ENVIRONMENTAL LIMITS

Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C). Maximum wet bulb temperature is 82°F (28°C).

2.7.1Temperature a. Operating

The drive meets the operating specifications over a 41°F to 140°F (5°C to 60°C) drive case temperature range with a maximum temperature gradient of 36°F (20°C) per hour.

The maximum allowable drive case temperature is 60°C. See Figure 9 for HDA case temperature measurement location

The MTBF specification for the drive assumes the operating environment is designed to maintain nominal case temperature. The rated MTBF is based upon a sustained case temperature of 104°F (40°C). Occasional excursions in operating temperature between the rated MTBF temperature and the maximum drive operating case temperature may occur without impact to the rated MTBF temperature. However, continual or sustained operation at case temperatures beyond the rated MTBF temperature will degrade the drive MTBF and reduce product reliability.

Air flow may be required to achieve consistent nominal case temperature values (see Section 3.4). To confirm that the required cooling is provided for the electronics and HDA, place the drive in its final mechanical configuration, and perform random write/read operations. After the temperatures stabilize, measure the case temperature of the drive.

b.Non-operating

–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification assumes that the drive is packaged in the shipping container designed by Seagate for use with drive.

HDA Temp.

Check Point

Figure 9. Location of the HDA temperature check point

NOTE

Image is for reference only, may not represent actual drive

2.7.2Humidity

2.7.2.1Relative humidity

Operating:

5% to 90% noncondensing (30% per hour max)

 

 

Nonoperating:

5% to 95% noncondensing (30% per hour max)

 

 

2.7.3Altitude

Operating:

–304.8 m to 3048 m (–1000 ft. to 10,000+ ft.)

 

 

Nonoperating:

–304.8 m to 12,192 m (–1000 ft. to 40,000+ ft.)

 

 

2.7.4Shock

All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting screws. Shock may be applied in the X, Y or Z axis.