4.4Drive mounting

You can mount the drive in any orientation using four screws in the side-mounting holes or four screws in the bottom-mounting holes. See Figure 4 for drive mounting dimensions. Follow these important mounting precau- tions when mounting the drive:

Allow a minimum clearance of 0.030 in (0.76mm) around the entire perimeter of the drive for cooling.

Use only 6-32 UNC mounting screws.

The screws should be inserted no more than 0.150 in (3.81mm) into the bottom or side mounting holes.

Do not overtighten the mounting screws (maximum torque: 6 in-lb).

[1]

5.787 (146.9898) max.

Recommended case temperature measurement location

 

1.122

 

 

 

 

1.638

 

 

 

 

 

(41.605)

[1]

 

+ .020

 

 

 

 

 

 

 

 

 

 

(28.499

 

 

 

 

 

 

 

 

 

 

 

 

+.508)

[1][1]

4.000

(101.6)

.250

+ .015

(6.35

+ .381)

(3x both sides)

4.000

(101.60)

.138

(3.505)

.814

(20.676)

C of conn. Datum B

L

2.00

(50.80)

C of drive

L

[1]

2 x 3.750

(2 x 95.25)

1.028 max [1]

(26.111 max)

Notes:

Dimensions are shown in inches (mm).

[1] Dimensions per SFF-8301 specification

2 x 1.625

(2 x 41.28) [1]

2 x 1.750 [1] (2 x 44.45)

4.000

(101.6)

[1]

Recommended case temperature measurement location

Figure 4. Mounting dimensions—top, side and end view

Constellation ES Serial ATA Product Manual, Rev. D

25

Page 31
Image 31
Seagate ST3500514NS, ST31000524NS, ST32000644NS manual Drive mounting, Mounting dimensions-top, side and end view