Seagate ST34311A Environmental tolerances Ambient temperature, Temperature gradient, Humidity

Models: ST34311A ST38421A ST32112A ST36421A

1 42
Download 42 pages 13.08 Kb
Page 19
Image 19

U4 Family Product Manual, Rev. D

11

drive buffer is enabled, the heads are parked and the spindle is at rest. The drive accepts all commands and returns to Active mode any time disc access is necessary.

Sleep mode

The drive enters Sleep mode after receiving a Sleep command from the host. In Sleep mode, the drive buffer is disabled, the heads are parked and the spindle is at rest. The drive leaves Sleep mode after it receives a Hard Reset or Soft Reset from the host. After receiving a reset, the drive exits Sleep mode and enters Active mode with all current translation parameters intact.

Idle and Standby timers

Each time the drive performs an Active function (read, write or seek), the standby timer is reinitialized and begins counting down from its specified delay times to zero. If the standby timer reaches zero before any drive activity is required, the drive makes a transition to Standby mode. In both Idle and Standby mode, the drive accepts all commands and returns to Active mode when disc access is necessary.

1.8 Environmental tolerances

1.8.1 Ambient temperature

Operating

0° to 55°C (32° to 131°F)

Nonoperating

–40° to 70°C (–40° to 158°F)

Note. Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet (3,048 meters). Operating ambient temperature is defined as the temperature of the environment immediately surrounding the drive.

1.8.2

Temperature gradient

Operating/Nonoperating 20°C/hr (36°F/hour) max, without condensation

1.8.3

Humidity

1.8.3.1 Relative Humidity

Operating

5% to 90% noncondensing (30% per hour max)

Nonoperating

5% to 95% noncondensing (30% per hour max)

Page 19
Image 19
Seagate ST34311A, ST32112A manual Environmental tolerances Ambient temperature, Temperature gradient, Relative Humidity