Table 16: 300 GB DC power requirements

Table 16: 300 GB DC power requirements

 

 

 

3 Gbit mode

 

6 Gbit mode

 

 

 

 

 

 

 

 

 

 

 

Notes

(Amps)

 

(Amps)

(Amps)

 

(Amps)

 

 

 

 

 

 

 

 

 

Voltage

 

 

+5V

 

+12V [2]

+5V

 

+12V [2]

 

 

 

 

 

 

 

 

 

Regulation

 

[5]

±5%

 

±5% [2]

±5%

 

±5% [2]

 

 

 

 

 

 

 

 

 

Avg idle current

 

[1] [7]

0.34

 

0.58

0.35

 

0.58

 

 

 

 

 

 

 

 

 

Maximum starting current

 

 

 

 

 

 

 

 

(peak DC) DC

3σ

[3]

0.53

 

1.92

0.54

 

1.92

(peak AC) AC

3σ

[3]

0.98

 

3.82

0.86

 

3.98

 

 

 

 

 

 

 

 

 

Delayed motor start (max) DC

3σ

[1] [4]

0.47

 

0.04

0.48

 

0.04

 

 

 

 

 

 

 

 

 

Peak operating current (random read):

 

 

 

 

 

 

 

 

Typical DC

[1][6]

[1]

0.41

 

0.88

0.42

 

0.90

Maximum DC

3σ

[1]

0.42

 

0.95

0.43

 

0.95

Maximum DC (peak)

3σ

 

1.18

 

2.78

1.20

 

2.74

 

 

 

 

 

 

 

 

 

Peak operating current (random write):

 

 

 

 

 

 

 

 

Typical DC

[1][6]

[1]

0.48

 

0.80

0.49

 

0.81

Maximum DC

3σ

[1]

0.49

 

0.83

0.51

 

0.82

Maximum DC (peak)

3σ

 

1.18

 

2.68

1.20

 

2.66

 

 

 

 

 

 

 

 

 

Peak operating current (sequential read):

 

 

 

 

 

 

 

 

Typical DC

[1][6]

[1]

0.91

 

0.59

0.92

 

0.59

Maximum DC

3σ

[1]

0.93

 

0.60

0.94

 

0.61

Maximum DC (peak)

3σ

 

1.20

 

0.98

1.24

 

1.00

 

 

 

 

 

 

 

 

 

Peak operating current (sequential write):

 

 

 

 

 

 

 

 

Typical DC

[1][6]

[1]

0.89

 

0.58

0.90

 

0.59

Maximum DC

3σ

[1]

0.93

 

0.60

0.94

 

0.60

Maximum DC (peak)

3σ

 

1.22

 

0.98

1.22

 

0.96

 

 

 

 

 

 

 

 

 

[1]Measured with average reading DC ammeter or equivalent sampling scope. Instantaneous +12V current peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.

[2]For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 15,000 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.

[3]See +12V current profile in Figure 1.

[4]This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive.

[5]See paragraph 7.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.

Cheetah 15K.7 SAS Product Manual, Rev. D