Momentus 4200.2 Product Manual, Rev. C
29
4.1.3 Set Features commandThis command controls the implementation of var ious features that the drive supports. When the dr ive r eceiv es this command, it sets BSY, checks the contents of the Features register, clears BSY and generates an inter-rupt. If the value in the register does not represent a feature that the drive supports, the command is aborted. Power-on default has the read look-ahead and write caching features enabled. The acceptable values for the Features register are defined as follows: Note. At power-on, or after a hardware or software reset, the default values of the features are as indicated above.
13 1 = 80-conductor cable detected, CBLID above VIH
0 = 40-conductor cable detected, CBLID below VIL
Table 8: Features register values
02HEnable write cache (default).
03H Set transfer mode (based on value in Sector Count register).
Sector Count register values:
00HSet PIO mode to default (PIO mode 2).
01HSet PIO mode to default and disable IORDY (PIO mode 2).
08HPIO mode 0
09HPIO mode 1
0AHPIO mode 2
0BHPIO mode 3
0CHPIO mode 4 (default)
20HMultiword DMA mode 0
21HMultiword DMA mode 1
22HMultiword DMA mode 2
40HUltra DMA mode 0
41HUltra DMA mode 1
42HUltra DMA mode 2
43HUltra DMA mode 3
44HUltra DMA mode 4
45HUltra DMA mode 5
05HEnable advanced power management
55HDisable read look-ahead (read cache) feature.
82HDisable write cache.
AAHEnable read look-ahead (read cache) feature (default).
F1HReport full capacity available