LED INDICATOR and OVERLOAD PROTECTION

The LED glows GREEN automatically when plugged into a 12V DC source and will not glow under the following conditions:

1.When the power input from the vehicle’s battery drops to approximately 10 volts, low battery shutdown occurs and inverter shuts off.

2.When the power input the vehicle’s battery exceeds 15 volts, high voltage overload protections occurs.

3.The continuous load demand from the equipment or device being operated exceeds 140 watts.

4.The case temperature become hot (exceeds 145°F).

Reset:

To reset after shutdown occurs, check the source of the problem and correct. Reinsert the inverter into the 12V ac- cessory outlet.

Page 9
Image 9
Sears 140 owner manual LED Indicator and Overload Protection, Reset