FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A.This appliancehas apilotwhichmust be lightedby
hand,Whenlightingthepilot,follow theseinstructions
exactly.
B.BEFORELIGHTINGsmellallaroundtheappliancearea
for gas.Be sure to smell next to the floor because
somegasisheavierthanair andwillsetUeonthefloor.
WHATTODOIFYOUSMELLGAS
Donottryto lightanyappliance.
Do not touchany electric switch;do not use any
phoneinyourbuilding.
,Immediatelycallyourgassupplierfroma neighbor's
phone°Followthegassupplier'sinstructions_
C.
D_
• If you cannotreachyour gas supplier,callthe fire
department.
Useonlyyourhandto pushin or turnthe gascontrol
knob.Neverusetools.If the knobwill not pushinor
turnby hand,don'ttryto repairit,calla qualified ser-
vicetechnician.Forceor attemptedrepairmayresult
ina fireorexplosion.
Donot usethis applianceifanypart has beenunder
water.Immedtzitelycall a qualified servicetechnician
toinspecttheapplianceandto replaceanypartofthe
controlsystemandanygas controlwhichhas been
underwater.
LiGHTiNG iNSTRUCTIONS
1oSTOP!Readthesafetyinformationaboveonthislabel.
2.Removeouterdoor.
3. Set thethermostat to lowestsettinq by turning the
watertemperaturedialclockwise,(( _,)to itslowest
temperaturesetting(witharrowon dial)as shown.DO
NOT FORCE.
4oTurngascontrolknobclockwlse_d'l to"OFF'*posi-
tion. Knobcannotbe turned from "PILOT" to "OFF"
unlessknobis depressedslightly.DO NOT FORCE.
(Figure6,page15)
5_Waitfive (5)minutesto clearout anygas° If youthen
smellgas,STOP!Follow"B" in thesafetyinformation
aboveon thislabel. If you don'tsmellgas, go to the
nextstep°
6oRemove(oropen) innerdoor locatedbelow the gas
controlunit,(Figure9,page15)
7.Find pilot-followmetaltubefromgascontrol.Thepilot
islocatedontherighthandsideoftheburner°
PILOT BURNER _THERMOCOUPLE
8.If you don't smell gas,turn knobon gascontrolcounter
c!ockwise_@ to"PILOT"position. (Figure7,page15)
9oPush in control knob all the way and hold down.
Immediatelylightthe pilotwithamatch.Continueto
holdcontrolknob in for aboutone (1) minuteafter
thepilotis lit. Releaseknoband it willpop backup.
Pilotshouldremainlit.If it goes out,repeatsteps 3
through8.
• If knobdoesnotpop upwhen released,stop and
immediatelycall your servicetechnicianor gas
supplier.
' If the pilot will not stay lit after several tries,
depressandturnthegascontrolknobclockwise
@_to"OFF'' andcallyourservicetechnician
orgassupplier.(Figure6,page15)
10.Replace(orclose)inner door°Replaceouter doorif
doordoesnot covergascontrolon/offknob or tem-
peratureadjustmentknob.(Figure9,page15)
1!. Atarmslength away,turngascontrolknobcounter-
clockwise _to the full "ON" position.
WARNING Donot use gas control knob to reg-
ulate gas flow. (Figure8,page15)
124Atarmslength away,set thethermostatto desired
setting.Themark( '_')HOTindicativeofapproximate
120°Fis preferredstarting point,Some locallaws
mayrequirea lowerstartingpoint.If hotterwateris
desired,see instructionmanualand"warning" below_
13oReplacetheouterdoorifnotreplacedinstep10.

WARNING

Hotterwaterincreases the riskof scald injury°Beforechangingtemperaturesettingseeinstructionmanual
TO TURN OFF GAS TO APPLIANCE
1oSetthethermostatto lowestsetting by turningthe 2. Turngascontrolknobclockwise_ 1to "OFF"posi.
watertemperaturedialclockwise(F-'_) to its lowest tion.Knobcannotbeturnedfrom "PILOT"to "OFF"
temperaturesetting(witharrowon dial)as shown.DO unlessknobis depressedslightly_DO NOT FORCE.
NOT FORCE, _(Figure6,page15)
3_Replaceouterdoor(ifremoved)_
]6