Sears 200.71522 Problem low or no output voltage, troubleshooting, Reason, Solution

Models: 200.71522

1 8
Download 8 pages 10.73 Kb
Page 7
Image 7
10. troubleshooting

10. troubleshooting

Problem: low or no output voltage

REASON

SOLUTION

Poor contact at terminal

Unplug and reinsert Power Inverter 140.

Equipment being operated is drawing

Use a higher capacity inverter or do not

too much power

use the device.

Inverter is too hot (thermal shut down)

Allow inverter to cool. Check for adequate

 

ventilation. Reduce the load on the in-

 

verter to rated continuous power output.

Fuse blows

A blown fuse is usually caused by reverse

 

polarity or a short circuit within the device

 

being operated. To replace:

 

• Disconnect the device immediately.

 

• Find the source of the problem and

 

repair it.

 

• Install a new 15-amp fuse. Do not

 

tighten the fuse cap too far; finger tight

 

is sufficient.

 

NOTE: Installing a fuse higher than 15-

 

amps may cause damage to the inverter.

Inverter may be defective

Call 1-800-SEARS-64 for troubleshooting

 

assistance.

5

Page 7
Image 7
Sears 200.71522 operating instructions Problem low or no output voltage, troubleshooting, Reason, Solution