Sears 449.32051 Before You Call For Service, Helpful Hints Checklist, B. Water Too Hot, lair

Models: 449.32051 449.320311 449.31041 449.310311 449.31051 449.31053 449.32031 449.32041 449.320511 449.310411 449.320411 449.31031 449.314410 SHORT 449.310531

1 16
Download 16 pages 253 b
Page 13
Image 13
BEFORE YOU CALL FOR SERVICE

BEFORE YOU CALL FOR SERVICE

WARNING

-

/

 

 

TO GUARD AGAINST SEVERE BURNS OR POSSIBLE FATALELECTRICAL SHOCK,

/

BE SURE TO TURN OFF ELECTRICAL POWER TO THE WATER HEATER BEFORE REMOVING ANY PANELS,

J

 

HELPFUL HINTS CHECKLIST

If your water heater fails to work right, make the following easy checks. Often, you will find what'swrong yourself and you won't

have to call and wait for service and hot water. If you do not find what'swrong when making the checks, then call for service.

PLEASE READTHE WARRANTY NOTES ON PAGE 16.

A.NOT ENOUGH OR NO HOT WATER

1.Used more hot water than the water heater holds, or faster than the water heater can heat the water.

2.Hot water wasted through leaking or partially open faucet.

3.If the water heater is newly installed, check the Installation Steps to be sure it'sinstalled correctly

(THIS IS A 240V WATER HEATERAND MUST BE WIRED TO A 240V SUPPLY).

4.Make sure the electrical supply is turned on and that the cold water supply valve is fully open.

5.Check for a blown fuse or popped circuit breaker (circuit breakers weaken with age and may not handle the rated load).

6.During winter months, the colder supply water takes longer to heat.

7.The temperature limitswitch (Page 10) may have opened the circuit ff water temperature reached the maximum limit.

8.Temperature controls for the heating elements set too low (Page 9).

9.Possible burned out element(s).

B.WATER TOO HOT

1.Temperaturecontrolsfor the heatingelements set too high (Page9).

2.Temperaturecontrolthermostat not working.

C.WATER LEAKS

NOTE: Always checkfor condensation first as the source of the "leak". Wipe all wet surfaces dry and check again. Also, the .., temperature and pressure relief valve may have opened to vent high pressure or temperature. Points to check on the water ' heater for possibleleaksare as follows.

CAUTION: TURN OFF ELECTRICALPOWER IF YOU WILL REMOVE THE ACCESS PANELS. Before repairinga leak, turn off the water supply and drain the tank (see Page 10).

1.Inlet and outletfittings.

2.Temperatureand pressure relief valveconnection, or the valve itself(see Pages 4 and 6).

3.Drain valve, or drain valvethreads to tank.

4.Gaskets around heating element(s).

NOTE: Improperly installed heat traps could cause reduCed or restricted water flow (see Pages 4 and 5).

lair] _

HEAT TRAP INSTALLATION

Install on V_ater Heater

inlet (COLD) Side

As Shown

Install on Water

Heater

Inse_

Outlet

(HOT}

Side

 

AS Shown

 

Pink In=ert

 

 

 

Water

 

 

 

)irection

Hot Side Trap

 

 

Water Flow

OirectiQn

 

1 _ x 3/4" Reducer

(included)

Page 13
Image 13
Sears 449.32051 Before You Call For Service, Helpful Hints Checklist, A. Not Enough Or No Hot Water, B. Water Too Hot