Important Safety Instructions

Risk to Breathing

&Guidelines

Avoid using the air compressor in confined areas. Always have adequate space (12 inches) on all sides of the air compressor. Also keep children, pets, and others out of the area of operation. This air compressor does not provide breathable air for anyone or any auxiliary breathing device. Spraying material will always need to be in another area away from the air compressor to not allow intake air to damage the air compressor filter.

Risk of Electrical Shock Never utilize the air compressor in the rain or wet conditions. Any electrical issues or repairs should be performed by authorized personnel such as an electrician and should comply with all national and local electrical codes. The air compressor should also have the proper three prong grounding plug, correct voltage, and adequate fuse protection.

Risk of

Explosion or Fire

Risk of Bursting

Never operate the compressor near combustible materials, gasoline or solvent vapors. If spraying flammable materials, locate the air compressor at least 20 feet away from the spray area. Never operate the air compres- sor indoors or in a confined area.

Always drain the air compressor tank daily or after each use. If the tank develops a leak, then replace the air compressor. Never use the air com- pressor after a leak has been found or try to make any modifications to the tank. Never modify the air compressor's factory settings which control the tank pressure or any other function.

Specifications

Pump

Oil-Free,

Direct Drive

Motor

1.5 HP

Bore

2.48"

Stroke

0.87"

Voltage

Single Phase

120 VAC

Minimum

Circuit Requirement

15 Amps

Glossary

CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure for air delivery.

PSIG: Pounds per square inch gauge; a unit of measure for pressure.

ASME: American Society of Mechanical Engineers.

California Code: Unit may comply with California Code 462 (I) (2)/(M) (2).

Cut-In Pressure: The air compressor will automatically start to refill the tank when the pressure drops below the prescribed minimum.

Air Tank Capacity

26 Gallons

Cut-in

Pressure

120

PSI

Cut-out

Pressure

150

PSI

SCFM

@ 90

PSI

 

3.8

SCFM

@ 40

PSI

 

5.1

Cut-Out Pressure: The point at which the motor stops when the tank has reached maximum air pressure.

Code Certification: Products that bear one or more

of the following marks: UL, CUL, ETL, CSA, have been evaluated by OSHA-certified independent safety laboratories and meet

the applicable Underwriters Laboratories Standards for Safety.

Duty

Cycle

 

 

 

This

is a

50% duty cycle

air compressor.

Do not run the air compressor

more than 30 minutes of

one

hour.

Doing so could

damage the air

compressor.

 

4