A sample motor current control is shown in Figure 3-8.

Less

More than More than than More than More than

2.5ms 2.5ms 2.5ms 2.5ms 2.5ms

 

 

 

 

Approx.

 

Motor drive

 

 

 

 

 

275

 

current

 

 

 

 

275mA)

 

 

4

 

 

 

 

 

 

10

 

 

 

 

 

0

10

Figure 3-8 Sample of Motor Current Control

Drive the motor at Im (approx. 275 mA) during the start-up step and the stop step. Do not switch the current.

Continuous driving

When the motor is driven for a long time or motor drive is often performed repeatedly, the motor heats up and may not be able to show necessary performance. To avoid it, when the motor was driven, set up the pause time of the same period of time as that the motor was driven. Furthermore, make onetime continuous driving 6 minutes (max.).