g. At this time, the shutter speed scale

and aperture scale

combination becomes the correct exposure.

 

Example: With High slide inserted, meter indicates 80 footcandles At ISO 100, the proper exposure becomes 1, 250 sec at F 5.6, 1; 30 sec at F!16 and 1 sec at F-90. h. By changing ISO setting, the set combination of shutter speed and aperture scale is automatically altered to the appropriate one corresponding to the changed ISO value.

*Meter scale intermediate values

intermediate values for shutter speed and aperture scale

*Film sensitivity intermediate values

Note: When no slide is inserted, strong light directly striking the slide slot may enter through the slot. Although this does not seriously affect exposure, if more accurate exposure is required, cover slot with hand.