Sennheiser MKH 800 manual Technical Data

Models: MKH 800

1 19
Download 19 pages 44.49 Kb
Page 12
Image 12

Technical Data

short description

high-frequency studio condenser

 

microphone with 5 switchable

 

directional characteristics

transducer type

double push-pull pressure-gradient

 

transducer

directional characteristics

omnidirectional, wide-angle cardioid,

 

cardioid, super cardioid, figure-8

frequency range

30 - 50000 Hz

sensitivity

40 mV/Pa ± ldB (-28 dB re 1 V/Pa)

output impedance

150 Ω

maximum SPL

136 dB SPL

 

(142 dB SPL with 6/12 dB preattenuation)

maximum output voltage

5 V

equivalent SPL due to inherent noise 20 dB SPL (CCIR-weighted)

 

10 dB SPL (A-weighted)

output voltage due to inherent noise

8 ∝ V (CCIR-weighted)

 

2.5 ∝ V (A-weighted)

S/N ratio at 94 dB SPL ( 1 Pa)

74 dB (CCIR-weighted)

 

84 dB (A-weighted)

dynamic range

116 dB (CCIR-weighted)

 

126 dB (A-weighted)

switchable pre-attenuation

6/12 dB (20/10 mV/Pa)

switchable bass rolI-off

3/6 dB at 50 Hz

switchable treble emphasis

3/6 dB at 8 kHz

feeding

phantom feeding P48

supply voltage / supply current

48 ± 4 V / 3 mA

connector

XLR-3

diameter

26.5 mm

length

178 mm

weight

135 g

Subject to alterations.

20

Page 12
Image 12
Sennheiser MKH 800 manual Technical Data