Sentry : Solutions for the Data Center Equipment Cabinet

Sentry Switched CDU

Key Features

CW-16V

CW-16V1

>Remote Power Management: Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles

>High Power Distribution: 120V, 208V, or 230V power; 20 or 30-Amp power input feed options

>High Density: Single power input feed; 16 outlets per enclosure

>IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP or RS-232 access

>Add an Expansion Module: Daisy chain the Switched CDU Expansion Module (CW/CX) for power management of separate power circuits from a single IP address

>Environmental Monitoring: Each Switched CDU supports two temperature & humidity probes and reports conditions thru the Web interface

>Enterprise View: View and access up to 1,000 Switched CDUs from one Web interface**

>SNMP Traps: Provide automated alerts for power and environmental conditions

>Input Current Monitor: Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display. Remote verification via browser or serial screen.

>Power-up Sequencing: Prevent an in-rush power overload

High-Density Power Distribution

The Switched CDU’s combine remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.

Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.

The Switched CDU also supports Enterprise View PDU Manager. This gives the engineer the ability to manage a large installation of

Networked CDUs from one location, view and access up to 1,000 Switched CDUs from a single web interface.

Additional Benefits:

Branch Circuit Protection

The Sentry CDU Family meets the new UL 60950-1 requirement for branch circuit protection.

Attention! The Sentry CDU products meet the above criteria by providing overcurrent protection with UL-listed Bussman SC fuses for each branch circuit.

Input Current Monitoring

The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.

Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds.

Page 1
Image 1
Server Technology CW-16V technical specifications Branch Circuit Protection, Input Current Monitoring

CW-16V specifications

The Server Technology CW-16V is a highly regarded power distribution unit (PDU) that has gained popularity for its efficiency and advanced features. Designed for data centers and IT environments, the CW-16V provides reliable power management and distribution, ensuring that critical equipment remains operational at all times.

One of the main features of the CW-16V is its 16 outlet configuration, allowing users to connect multiple devices simultaneously. This PDU comes with branch circuit protection, which is essential for preventing overload situations that could potentially damage connected equipment. With a robust design that supports power demands, the CW-16V is capable of handling a wide range of electrical loads, making it suitable for various applications.

The CW-16V incorporates advanced technologies to enhance monitoring and management capabilities. It is equipped with an integrated network interface that enables remote management, allowing administrators to monitor real-time power usage, energy consumption, and environmental conditions. This feature is crucial for optimizing energy efficiency and minimizing operational costs in data centers.

In terms of characteristics, the CW-16V boasts a rugged construction designed to withstand the rigors of data center environments. Its durable housing provides protection against dust and damage, while its compact form factor allows for easy installation in both rack-mounted and standalone configurations. The PDU is also designed for easy access to outlets, simplifying device connectivity and maintenance.

One standout characteristic of the CW-16V is its compatibility with various input and output options. It supports multiple voltage configurations, making it versatile for different types of equipment. The PDU also features intelligent load balancing capabilities that ensure even distribution of power, preventing potential hotspots and enhancing overall system reliability.

In conclusion, the Server Technology CW-16V is a sophisticated power distribution solution that effectively combines reliability, efficiency, and advanced monitoring capabilities. Its comprehensive features, such as multiple outlets, remote management, and robust construction, make it an ideal choice for data center operators looking to optimize their power distribution strategy. As data center demands continue to evolve, the CW-16V stands out as a dependable choice for maintaining the integrity and performance of critical IT infrastructure.