Sharp AC880 Recover/Recycle, X X . X L B, R E C Y C L E H O L D, S T A R T ?, C H E C K, L B #

Models: AC880

1 19
Download 19 pages 30.9 Kb
Page 7
Image 7
R E C Y C L E H O L D

W E I G H T =

X X . X L B

A U T O M A T I C ?

#

 

 

 

 

 

>

 

 

 

 

 

W E I G H T =

X X . X L B

R E C Y C L E

?

#

 

 

 

 

 

ENTER

 

 

 

R E C Y C L E H O L D

 

T I M E

X X

M I N

#

 

 

 

>< ENTER

 

 

C H E C K

H O S E S

 

S T A R T ?

 

#

 

 

ENTER

 

 

 

W E I G H T =

X X . X L B

C O M P R E S S O R O N

 

 

 

 

 

W E I G H T =

X X . X L B

C O M P R E S S O R O F F

 

 

A M O U N T R E C Y C L E D =

 

 

X X . X

L B #

 

 

 

 

ENTER

D R A I N R E C O V E R E D

O I L N O W !

#

 

 

ENTER

 

*

 

H I G H P R E S S U R E

 

S E E M A N U A L

 

 

 

**

 

C Y L I N D E R F U L L

 

G O T O C H A R G E

#

 

 

RECOVER/RECYCLE

1.Set up the AC880 and turn the Main Power Switch ON.

2.Attach the Red and Blue Hoses to the A/C System per the vehicle manufacturer's instructions, open the Red and Blue Hose Valves.

3.Using the Keypad, press the “Up Arrow” key one time to display “WEIGHT= XX.X LB” “RECYCLE? #” and press the ENTER key. The Display will read “RECYCLE HOLD” “TIME XX MIN #”.

The Recycle Hold Time is the amount of time that the AC880 waits for “out- gassing” or for the pressure in the A/C System to rise enough to automatically restart the recovery process. The minimum value is two minutes. The value entered is stored in memory and displays as the default value the next time the procedure is used.

4.Press the “Up Arrow” key to change the value of the field. Press the “Right Arrow” key to change to a different field. Press the ENTER key to accept the value. The Display will then read “CHECK HOSES” “START? #”.

5.Press the ENTER key to start recovering and recycling with the AC880.

The Display will read the “WEIGHT= XX.X LB” “COMPRESSOR ON”. The AC880 will recover and recycle refrigerant from the A/C System and automatically cycle OFF when a vacuum is sensed. This vacuum level can be seen on the Low Pressure Gauge. The Display will read “WEIGHT= XX.X LB”

“COMPRESSOR OFF”

A small quantity of refrigerant will probably remain in the A/C System as observed by an increasing pressure on the Low Pressure Gauge. The AC880 will automatically cycle ON to continue recovering refrigerant if pressure rises to a preset level. This automatic cycling will repeat, resetting the Recycle Hold Timer each time. When the AC880 remains OFF for the duration of the Recycle Hold Timer value entered in Step 4 the Display will read “AMOUNT RECYCLED=” “XX.X LB #” from the A/C System and the Attention Light will turn ON.

6.Close the Red and Blue Hose Valves and disconnect the hoses from the A/C System.

7.Press the ENTER key. The Display will read “DRAIN RECOVERED OIL NOW!”. Drain any recovered oil using the Drain Recovered Oil procedure on Page 7.

8.Press the ENTER key to return to the Main Menu.

*This screen will display if there is an internal fault. Turn the AC880 Main Power Switch OFF. Contact RTI Technical Support.

**This screen will display when the Charging Cylinder fills to capacity, approximately 17.5 lbs (8 Kg.) If this occurs, the Weight can be lowered using the Charge procedure on Page 9 before the AC880 can be used to recover more refrigerant. Press the ENTER key to return to the Main Menu.

Page 6

Page 7
Image 7
Sharp AC880 Recover/Recycle, X X . X L B, R E C Y C L E H O L D, S T A R T ?, C O M P R E S S O R O F F, C H E C K, L B #