Sharp EL506XBWH specifications English, Operation Manual

Models: EL506XBWH

1 1
Download 1 pages 33.12 Kb
Page 1
Image 1
ENGLISH

 

ENGLISH

SCIENTIFIC CALCULATOR

EL-506V

MODEL EL-546V

OPERATION MANUAL

PRINTED IN CHINA / IMPRIMÉ EN CHINE 00LUP (TINSK0443EHZZ)

INTRODUCTION

About operation examples, please refer to the attached sheet. Refer to the number on the right of each title for use.

After reading this manual, store it in a convenient location for future reference.

Note : One of the models described in this manual may not be available in some countries.

Operational Notes

To ensure trouble-free operation, please observe the following points:

1.Do not carry the calculator in the back pocket of slacks or trousers.

2.Do not subject the calculator to extreme temperatures.

3.Do not drop it or apply excessive force.

4.Clean only with a soft, dry cloth.

5.Do not use or store the calculator where fluids can splash onto it. Press the RESET switch only in the following cases:

When using for the first time

After replacing the batteries

To clear all memory contents

When an abnormal condition occurs and all keys are inopera-

tive.

If service should be required on this calculator, use only a SHARP servicing dealer, SHARP approved service facility, or SHARP re- pair service where available.

Determination of the Angular Unit

This calculator has three angular units: DEG (°), RAD (Radians) and GRAD (g).

Press @Gto specify the angular unit.

SCIENTIFIC CALCULATIONS

Press @m0to select the normal mode.

In each example, press ªto clear the display. And if the FIX, SCI, or ENG indicator is displayed, clear the indicator by press- ing @f.

Arithmetic Operations

(2)

The closing parenthesis )just before =or ;may be omitted.

Constant Calculations

(3)

In the constant calculations, the addend becomes a constant. Subtraction and division are performed in the same manner. For multiplications, the multiplicand becomes a constant.

When performing calculations using constants, constants will be displayed as K.

Functions

(4)

Refer to operation examples of each function.

Before starting calculations, specify the angular unit.

Differential/Integral Functions

(5)

Differential and integral calculations are only available in the nor- mal mode. For calculation conditions such as the x value in differ- ential calculation or the initial point in integral calculation, only numerical values can be entered and equations such as 22 cannot be specified. It is possible to reuse the same equation over and over again and to recalculate by only changing the conditions without re-entering the equation.

When performing a calculation, the value stored in the X memory

 

will be cleared.

When performing a differential calculation, enter formula first

Time, Decimal and Sexagesimal Calculations

(11)

Conversion between decimal and sexagesimal numbers can be performed. In addition, the four basic arithmetic operations and memory calculations can be carried out using the sexagesimal system.

Coordinate Conversions

(12)

• Before performing a calculation, select the angular unit.

Y

 

P (x,y)

Y

 

P (r,θ )

y

 

 

 

r

0

 

X

0

θ

X

x

 

Rectangular coord. Polar coord.

• Refer to the Note of the Memory Calculations section.

Calculations Using Physical Constants

(13)

See the quick reference card and the other side of the “Operation Examples” sheet.

A constant is recalled by pressing ßfollowed by the number of the physical constant. You have to designate the physical constant using 2-digit numbers. For example, speed of light in vacuum should be designated as “01”.

The recalled constant appears in the display mode selected with the designated number of decimal places.

Physical constants can be recalled in the normal mode (when not set to binary, octal, or hexadecimal), 3-VLE mode, or statistics mode.

Note: Physical constants and metric conversions are based either on the 1986 values released by the Committee on Data for Science and Technology (CODATA) of ICSU (International Council of Scientific Unions) or on ISO specifications.

Metric Conversions

(14)

See the quick reference card and the other side of the “Operation Examples” sheet.

Unit conversions can be performed in the normal (when not set to

 

 

y

 

Means of samples (y data)

2

sy

Sample standard deviation (y data)

σ

y

Population standard deviation (y data)

Σ

y

Sum of samples (y data)

 

Σ

y 2

Sum of squares of samples (y data)

 

Σ

x y

Sum of products of samples (x, y)

 

 

r

Correlation coefficient

 

 

a

Coefficient of regression equation

 

 

b

Coefficient of regression equation

 

 

c

Coefficient of quadratic regression equation

 

 

 

 

 

Entered data are kept in memory until @cor @m

3are pressed. Before entering new data, clear the memory contents.

[Data Entry] Single-variable data

Data k

Data & frequency k (To enter multiples of the same data)

Two-variable data

Data x &Data y k

Data x &Data y &frequency k(To enter multiples of the same data x and y.)

[Data Correction]

Correction prior to pressing k: Delete incorrect data with ª.

Correction after pressing k:

The inputted statistical data can be traced back by pressing [. Display the data to correct, press @Jto delete, then input the correct value.

Statistical Calculation Formulas

(22)

Refer also to the operation examples sheets.

Type

Regression formula

Linear

y = a + bx

Exponential

y = a ebx

Hard Case

DISPLAY

Equation OPERATION MANUALManual backgroundManual backgroundManual background Display Manual background

Manual backgroundManual background Symbol

and then enter x value in differential calculation and minute

interval (dx). If a numerical value is not specified for minute

interval, x0 will be x10–4and x=0 will be 10–4from the value of

the numeric derivative.

• When performing a integral calculation, enter formula first and

then enter a range of integral (a, b) and subintervals (n). If a

numerical value is not specified for subintervals, calculation will

be performed using n=100.

Since differential and integral calculations are performed based on the following equations, correct results may not be obtained, in certain rare cases, when performing special calculations which contain discontinuous points.

Integral calculation (Simpson’s rule):

binary, octal, or hexadecimal), 3-VLE and statistics modes.

Modify Function

(15)

In this calculator, all calculation results are internally obtained in scientific notation with up to 12 digits for the mantissa. However, since calculation results are displayed in the form designated by the display notation and the number of decimal places indicated, the internal calculation result may differ from that shown in the display. By using the modify function, the internal value is con- verted to match that of the display, so that the displayed value can be used without change in subsequent operations.

SIMULATION CALCULATION

(16)

Logarithmic

y = a + b • ln x

Power

y = a xb

Inverse

1

y = a + b

 

x

 

 

Quadratic

y = a + bx + cx2

In the statistical calculation formulas, an error will occur when:

the absolute value of the intermediate result or calculation result is equal to or greater than 1 10100.

the denominator is zero.

an attempt is made to take the square root of a negative number.

no solution exists in the quadratic regression calculation.

Normal Probability Calculations

(19) (23)

Mantissa Exponent

(During actual use not all symbols are displayed at the same time.)

/: Appears when the entire equation cannot be displayed. Press </>to see the remaining (hidden) section.

xy/rθ : Indicates the mode of expression of results in the com- plex calculation mode.

2ndF : Appears when @is pressed, indicating that the func- tions shown in orange are enabled.

ALPHA : Indicates that @ K or O (R) has been pressed, and entry (recall) of memory contents and recall of statistics can be performed.

FIX/SCI/ENG: Indicates the notation used to display a value and changes each time @fare pressed.

DEG/RAD/GRAD: Indicates angular units and changes each time @Gis pressed.

ALGB : Appears when a simulation calculation is executed.

STAT : Appears when statistics mode is selected.

M: Indicates that a numerical value is stored in the inde- pendent memory.

?: Indicates that the calculator is waiting for a numerical value to be entered, such as during simulation calcula- tion.

:Appears when the calculator shows an angle as the result in the complex calculation mode.

i: Indicates an imaginary number is being displayed in the complex calculation mode.

BEFORE USING THE CALCULATOR

Key Notation Used in this Manual

In this manual, key operations are described as follows:

ex xE

To specify ex

: @e

ln

To specify E (HEX) : E

 

To specify ln

: I

 

To specify X

: @KX

Functions that are printed in orange above the key require @to be pressed first before the key. Numbers are not shown as keys, but as ordinary numbers.

Power On and Off

Press ªto turn the calculator on, and @ Fto turn it off.

Clearing Methods

There are three clearing methods as follows:

Clearing

Entry

M

A-D, X,Y

operation

(Display)

F1, F2

STAT, ANS*1

ª

 

@c

 

 

RESET

 

 

 

: Clear

: Retain

 

*1 Statistical data and last answer memory. Refer to the Memory Calculations section.

Editing the Equation

Press <or >to move the cursor. You can also return to the equation after getting an answer by pressing >(<). See below for Multi-line playback function.

If you need to delete a number, move the cursor to the number you wish to delete then press d.

The number under the cursor will be deleted.

If you need to insert a number, move the cursor to the place immediately after where you wish to insert the number then enter the number.

Multi-line Playback function

(1)

This calculator is equipped with a function to recall previous equa- tions. Equations also include calculation ending instructions such as “=” and a maximum of 142 characters can be stored in memory. When the memory is full, stored equations are deleted in the order of the oldest first. Pressing [will display the previous equa- tion. Further pressing [will display preceding equations (after returning to the previous equation, press ]to view equations in order). In addition, @[can be used to jump to the oldest equation.

The multi-line memory is cleared by the following operations: @c, mode change, RESET, and N-base conversion.

For EL-546V, in addition to the above, pressing @F (including the Automatic Power Off feature) will also clear the multi-line memory.

Priority Levels in Calculation

This calculator performs operations according to the following pri- ority:1

2Functions preceded by their argument (x-1, x2, n!, etc.) 3 Yx, x¿ 4Implied multiplication of a memory value (2Y, etc.) 5

unctions followed by their argument (sin, cos, etc.) 6Implied Fmultiplication of a function (2sin30, etc.) 7nCr, nPr 8, ÷ 9+, – AND GOR, XOR, XNOR H=, M+, M–, M, DEG, RAD, GRAD, DATA, CD, rθ , xy and other calculation ending in-

struction

If parentheses are used, parenthesized calculations have prec- edence over any other calculations.

INITIAL SETUP

Mode Selection

Normal mode (NORMAL): @m0

Used to perform arithmetic operations and function calculations.

Complex number mode (CPLX): @m1

Used to perform arithmetic operations with complex numbers.

3-VLE mode (3-VLE): @m2

Used to perform simultaneous linear equations with three unknowns.

Statistic mode (STAT): @m3

Used to perform statistical calculations.

When executing mode selection, temporary memories, statistical data and last answer memory will be cleared even when reselecting the same mode.

Selecting the Display Notation and Decimal Places

The calculator has four display notation systems for displaying calculation results. When FIX, SCI, or ENG symbol is displayed, the number of decimal places can be set to any value between 0 and 9. Displayed values will be reduced to the corresponding number of digits.

100000÷3=

ª100000/3= 33333.33333

[Floating point]

[FIXed decimal point]

@f

33333.33333

[TAB set to 2]

@i2

33333.33

[SCIentific notation]

@f

3.33104

[ENGineering notation]

@f

33.33103

[Floating point]

@f

33333.33333

If the value for floating point system does not fit in the following range, the calculator will display the result using scientific notation

system:

0.000000001 x 9999999999

1

 

h=

ba

S=— h{ƒ (a)+4{ƒ (a+h)+ƒ (a+3h)+······+ƒ (a+(N–1)h)}

N

3

 

 

+2{ƒ (a+2h)+ƒ (a+4h)+······+ƒ (a+(N–2)h)}+f(b)}

N=2n

a x b

 

 

Differential calculation:

 

 

 

 

 

dx

dx

 

 

 

 

f (x+ ––)–f(x––)

 

 

 

 

2

2

 

 

 

 

f’(x) =————————

 

 

 

 

 

dx

[When performing integral calculations]

 

 

Integral calculations, depending on the

 

 

integrands and subintervals included, require

 

 

longer calculation time. During calculation,

y

 

“Calculating!” will be displayed. To cancel cal-

 

 

culation, press ª. In addition, please note

 

 

that there will be greater integral errors when

 

 

there are large fluctuations in the integral val-

 

 

ues during minute shifting of the integral range

a

b x

and for periodic functions, etc., where positive

x0

x1

 

x2

and negative integral values exist depending

 

x3

y

 

on the interval.

x2

x0

For the former case, divide integral intervals

a

b

as small as possible. For the latter case,

x

x1

x 3

separate the positive and negative values.

 

 

Following these tips will allow results of cal-

 

 

culations with greater accuracy and will also

 

 

shorten the calculation time.

 

 

Random Numbers

Apseudo-random number with three significant digits can be gen- erated by pressing @` =. To generate the next ran- dom number, press =. You can perform this function in the normal and statistics modes. (You cannot perform this function while you are using the N-Base function.)

• Random numbers use memory Y. Each random number is gen- erated on the basis of the value stored in memory Y (pseudo- random number series).

Angular Unit Conversions

(6)

Each time @g are pressed, the angular unit changes in sequence.

Memory Calculations

(7)

The calculator has six temporary memories (A-D, X and Y), one independent memory (M) and one last answer memory (ANS). EL- 506V is also equipped with formula memories (F1 and F2) for storing formulas.

Mode

ANS

M, F1, F2

A-D, X,Y

Normal

 

 

 

Complex

 

 

3-VLE

Statistic

 

: Available

: Unavailable

 

[Temporary memories (A-D, X and Y)]

A stored value can be recalled as a value or variable for the use in equations.

In case you store an infinite decimal in the memory, recall it as a variable to obtain accurate answers.

Ex.) 1

/3 OY

(0.3333...is stored to Y)

3

*RY=

0.999999999

3 *@KY= 1.

[Independent memory (M)]

In addition to all the features of temporary memories, a value can be added to or subtracted from an existing memory value.

[Last answer memory (ANS)]

The calculation result obtained by pressing = or any other calculation ending instruction is automatically stored in the last answer memory.

[Formula memories (F1 and F2)] : available only on EL-506V Formulas up to 80 characters each can be stored. As with storing numerical values in the memory, storing a new equation will auto- matically replace any existing equation in memory without notifica- tion.

Note:

Calculation results from the functions indicated below are auto- matically stored in memories X or Y. For this reason, when using these functions, be careful with the use of memories X and Y.

Random numbers .................. Y memory

rθ , xy ............................... X memory (r or x), Y memory (θ or y)

Temporary memories and last answer memory are cleared even when the same mode is reselected.

Chain Calculations

(8)

This calculator allows the previous calculation result to be used in the following calculation.

The previous calculation result will not be recalled after entering multiple instructions.

Fraction Calculations

(9)

This calculator performs arithmetic operations and memory calcu- lations using a fraction, and conversion between a decimal number and a fraction.

In all cases, a total of up to 10 digits including integer, numera- tor, denominator and the symbol (l) can be entered.

If the number of digits to be displayed is greater than 10, the number is converted to and displayed as a decimal number.

A decimal number, variable, or exponent cannot be used in a fraction.

Binary, Octal, Decimal, and Hexadecimal Operations

(N-Base)

(10)

This calculator can perform conversions between numbers ex- pressed in binary, octal, decimal and hexadecimal systems. It can also perform the four basic arithmetic operations, calculations with parentheses and memory calculations using binary, octal, decimal, and hexadecimal numbers. In addition, the calculator can carry out the logical operations AND, OR, NOT, NEG, XOR and XNOR on binary, octal and hexadecimal numbers.

Conversion to each system is performed by the following keys: : Converts to the binary system.Manual background” appears. : Converts to the octal system.Manual background” appears. : Converts to the hexadecimal system.Manual background” appears.

: Converts to the decimal system. ”, ”, and ” disappear from the display.

Conversion is performed on the displayed value when these keys are pressed.

Note: In this calculator, the hexadecimal numbers A – F are entered

by pressing ë, Ñ, É, é, ç, and ,

and displayed as follows:

A → ï, B → ∫, C → ó, D → ò, E → ô, F → ö

In the binary, octal, and hexadecimal systems, fractional parts cannot be entered. When a decimal number having a fractional part is converted into a binary, octal, or hexadecimal number, the fractional part will be truncated. Likewise, when the result of a binary, octal, or hexadecimal calculation includes a fractional part, the fractional part will be truncated. In the binary, octal, and hexa- decimal systems, negative numbers are displayed as a comple- ment.

If you have to find a value consecutively using the same formula, such as plotting a curve line for 2x2 + 1, or finding the variable for 2x + 2y =14, once you enter the equation, all you have to do is to specify the value for the variable in the formula.

Usable variables: A-D, M, X and Y

Unusable functions: RANDOM

Simulation calculations can only be executed in the normal mode.

Calculation ending instructions (%, etc.) other than =cannot be used.

1Performing Calculations

2Press m0.

3Input a formula with at least one variable.

4Press .

Variable input screen will appear. Input the value of the flashing variable, then press ®to confirm. The calculation result will be displayed after entering the value for all used variables.

Only numerical values are allowed as variables. Input of for- mulas are not permitted.

Upon completing the calculation, press to perform cal- culations using the same formula.

Variables and numerical values stored in the memories will be displayed in the variable input screen. To change a numerical value, input the new value and press ®.

COMPLEX NUMBER CALCULATIONS

(17)

To carry out addition, subtraction, multiplication, and division using complex numbers, press @m1 to select the complex number mode.

There are two modes of expression of the results of complex

1number calculations.

Rectangular coordinate mode. (x y appears on the display.)

2∑2

Polar coordinate mode. (rθ appears on the display.)

∑1

1Complex number entry

Rectangular coordinates x-coordinate+y-coordinateÜ

2or x-coordinate y-coordinate

Polar coordinates r Öθ

r: absolute value

θ : argument

Upon changing to another mode, the imaginary portion of any complex number stored in the independent memory (M) will be cleared.

A complex number expressed in rectangular coordinates with the y-value equal to zero, or expressed in polar coordinates with the angle equal to zero, is treated as a real number.

SIMULTANEOUS LINEAR EQUATIONS

WITH THREE UNKNOWNS

(18)

To solve simultaneous linear equations with three unknowns, press @m2to select the 3-VLE mode.

Simultaneous Linear Equations with Three Unknowns:

a1x + b1y + c1z = d1

 

 

 

a1 b1 c1

 

 

 

a2x + b2y + c2z = d2

 

D

=

a2 b2 c2

a3x + b3y + c3z = d3

 

 

 

a3 b3 c3

 

 

 

 

 

Notes: • If the determinant D = 0, an error occurs.

If the absolute value of an intermediate result or calcu- lation result is 1 10100 or more, an error occurs.

1Performing Calculations

2Press @m2.

Enter each coefficient from a1 to d3 followed by ®, as

3prompted on the display.

Upon pressing ®after entering d3, the solution for x will be displayed. Subsequent pressing will cycle through the values of y, z and the determinant D.

• Coefficients can be entered using ordinary arithmetic operations.

• To clear the entered coefficients, press @c.

Note: Pressing ® when the determinant D is in the display recalls the coefficients. Each time ®is pressed, a coeffi- cient is displayed in the order of input, allowing the entered coefficients to be verified. (by pressing , coeffi- cients are displayed in reverse order.)

To correct a particular coefficient being displayed, enter the correct value and then press ®.

If the coefficients c1, c2 and c3 as well as a3 – d3 are set to zero, the problem is treated as a 2-dimensional simultaneous equation. The x and y values as well as the determinant can be retrieved.

STATISTICAL CALCULATIONS

Statistical calculations are performed in the statistics mode. Press @m3to select the statistics mode. This calculator per- forms the seven statistical calculations indicated below. After se- lecting the statistics mode, select the desired sub-mode by press- ing the number key corresponding to your choice.

When changing to the statistical sub-mode, press the correspond- ing number key after performing the operation to select the statis- tics mode (press @m3).

0(STAT 0) : Single-variable statistics

1(STAT 1) : Linear regression calculation

2(STAT 2) : Quadratic regression calculation

3(STAT 3) : Exponential regression calculation

4(STAT 4) : Logarithmic regression calculation

5(STAT 5) : Power regression calculation

6(STAT 6) : Inverse regression calculation

The following statistics can be obtained for each statistical calcula- tion (refer to the table below):

Single-variable statistical calculation

(19)

Statistics of 1and value of the normal probability function

 

Linear regression calculation

(20)

Statistics of 1and 2and, in addition, estimate of y for a given x (estimate y´) and estimate of x for a given y (estimate x´)

Exponential regression, Logarithmic regression, Power regression, and Inverse regression calculation

Statistics of 1and 2. In addition, estimate of y for a given x and estimate of x for a given y. (Since the calculator converts each formula into a linear regression formula before actual calculation takes place, it obtains all statistics, except coefficients a and b, from converted data rather than entered data.)

Quadratic regression calculation

(21)

Statistics of 1and 2and coefficients a, b, c in the quadratic regression formula (y = a + bx + cx2). (For quadratic regression calculations, no correlation coefficient (r) can be obtained.) When there are two x´ values, press @≠.

When performing calculations using a, b and c, only one numeric value can be held.

 

 

x

 

Mean of samples (x data)

1

sx

Sample standard deviation (x data)

 

σ x

Population standard deviation (x data)

 

n

Number of samples

 

Σ x

Sum of samples (x data)

 

Σ x 2

Sum of squares of samples (x data)

Refer also to the operation examples sheet.

P(t), Q(t), and R(t) will always take positive values, even when t<0, because these functions follow the same principle used when solving for an area.

Values for P(t), Q(t), and R(t) are given to six decimal places.

ERROR AND CALCULATION RANGES

Errors

An error will occur if an operation exceeds the calculation ranges, or if a mathematically illegal operation is attempted. When an error occurs, pressing <(or >) automatically moves the cursor back to the place in the equation where the error occurred. Edit the equation or press ªto clear the equation.

Error Codes and Error Types

Syntax error (Error 1):

An attempt was made to perform an invalid operation. Ex. 2 +-5 =

Calculation error (Error 2):

The absolute value of an intermediate or final calculation result equals or exceeds 10100.

An attempt was made to divide by 0.

The calculation ranges were exceeded while performing calculations.

Depth error (Error 3):

The available number of buffers was exceeded. (There are 8 buffers* for numeric values and 16 buffers for calculation instructions). *4 buffers in STAT and the complex number mode.

Equation too long (Error 4):

The equation exceeded its maximum input buffer (142 characters). An equation must be shorter than 142 characters.

Equation recall error (Error 5):

The stored equation contains a function not available in the mode used to recall the equation. For example, if a numerical value with numbers other than 0 and 1 is stored as a decimal, etc., it cannot be recalled when the calculator is set to binary.

Calculation Ranges

(24)

Refer also to the operation examples sheet.

Within the ranges specified, this calculator is accurate to ±1 in the least significant digit of the mantissa. When performing con- tinuous calculations (including chain calculations), errors accu- mulate leading to reduced accuracy.

Calculation ranges

±10-99– ±9.9999999991099 and 0.

If the absolute value of an entry or a final or intermediate result of a calculation is less than 10–99, the value is considered to be 0 in calculations and in the display.

BATTERY REPLACEMENT

Notes on Battery Replacement

Improper handling of batteries can cause electrolyte leakage or explosion. Be sure to observe the following handling rules:

Replace both batteries at the same time.

Do not mix new and old batteries.

Make sure the new batteries are the correct type.

When installing, orient each battery properly as indicated in the calculator.

When to Replace the Batteries

If the display has poor contrast or nothing appears on the display even when ªis pressed in dim lighting, it is time to replace the batteries.

Caution

Keep batteries out of the reach of children.

Exhausted batteries left in the calculator may leak and damage the calculator.

Explosion risk may be caused by incorrect handling.

Batteries must be replaced only with others of the same type.

Do not throw batteries into a fire as they may explode.

Replacement Procedure

1.Turn the power off by pressing @F.

2.Remove two screws. (Fig. 1)

3.Slide the battery cover slightly and lift it to remove.

4.Remove the used batteries by prying them with a ball-point pen or other similar pointed device. (Fig. 2)

5.Install two new batteries. Make sure the “+” side facing up.

6.Replace the cover and screws.

7.Press the RESET switch (on the back).

Make sure that the display appears as shown below. If the display does not appear as shown, remove the batteries reinstall them and check the display once again.

(Fig. 1)

(Fig. 2)

Automatic Power Off Function

This calculator will turn itself off to save battery power if no key is pressed for approximately 10 minutes.

SPECIFICATIONS

Calculations:

Scientific calculations, complex number

 

calculations, simultaneous linear

 

equations with three unknowns, statistical

 

calculations, etc.

 

Internal calculations:

Mantissas of up to 12 digits

 

Pending operations:

16 calculations 8 numeric values

 

(4 numeric values in STAT and complex

 

number mode)

 

Power source:

Built-in solar cells

 

 

3V (DC):

 

 

 

Backup batteries (Alkaline batteries (LR44)

 

2)

 

 

Operating temperature:

0°C – 40°C (32°F – 104°F)

 

External dimensions:

78.6 mm (W)

152 mm (D)

10.5 mm (H)

 

3-3/32” (W)

5-31/32” (D)

13/32” (H)

Weight:

Approx. 78 g ( 0.172 lb)

 

 

(Including batteries)

 

Accessories:

Batteries 2 (installed), operation

manual, operation examples sheet, quick reference card (Physical Constants and Metric Conversions) and hard case

FOR MORE INFORMATION ABOUT THIS

CALCULATOR

Visit our Web site.

http://sharp-world.com/calculator/

Page 1
Image 1
Sharp EL506XBWH specifications English, Operation Manual