TV

Item Model: LC-90LE745U
LCD panel Size 90o Class (90 1/64o Diagonal)
Resolution 2,073,600 pixels (1,920 g 1,080)
TV
Function
TV-standard (CCIR) American TV Standard ATSC/NTSC System
Receiving
Channel
VHF/UHF VHF 2-13ch, UHF 14-69ch
CATV 1-135ch (non-scrambled channel only)
Digital Terrestrial Broadcast
(8VSB) 2-69ch
Digital cable*1 (64/256 QAM) 1-135ch (non-scrambled channel only)
Audio multiplex BTSC System
Audio out 10W g 2 + 15W (WF)
Terminals
Back panel
vertical inputs
HDMI 1 HDMI in with HDCP, ARC
HDMI 2 HDMI in with HDCP, Audio in (Ø 3.5 mm stereo jack)
HDMI 3 HDMI in with HDCP
HDMI 4 HDMI in with HDCP, MHL
AUDIO OUT Audio out (Ø 3.5 mm stereo jack)
USB 1 Photo/Music/Video mode, Software update
Back panel
surface inputs
COMPONENT COMPONENT in
VIDEO 1 AV in
VIDEO 2 AV in
PC IN ANALOG RGB (PC) in (15-pin mini D-sub female connector),
Audio in (Ø 3.5 mm stereo jack)
RS-232C 9-pin D-sub male connector
Back panel
horizontal inputs
ANT/CABLE 75 q Unbalance, F Type g 1 for Analog (VHF/UHF/CATV) and
Digital (AIR/CABLE)
AUDIO IN Audio in (Ø 3.5 mm stereo jack)
DIGITAL AUDIO OUTPUT Optical Digital audio output g 1 (PCM/Dolby Digital)
ETHERNET Network connector
USB 2 Photo/Music/Video mode, Software update
OSD language English/French/Spanish
Power Requirement AC 120 V, 60 Hz
Power Consumption 381 W (0.1 W Standby with AC 120 V)
Weight TV + stand 150.0 lbs./68.0 kg
TV only 141.1 lbs./64.0 kg
Dimensions*2 (W g H g D) TV + stand 80 7/8g 48 61/64 g 17 3/32 inches
TV only 80 7/8g 47 11/16 g 4 37/64 inches
Operating temperature e32°F to e104°F (0°C to e40°C)
*1 Emergency alert messages via Cable are unreceivable.
*2 The dimensional drawings are shown on the inside back cover.

• As part of policy of continuous improvement, SHARP reserves the right to make design and specifi cation changes for

product improvement without prior notice. The performance specifi cation fi gures indicated are nominal values of production

units. There may be some deviations from these values in individual units.

Cautions regarding use in high and low temperature environments

• When the unit is used in a low temperature space (e.g. room, offi ce), the picture may leave trails or appear slightly delayed.
This is not a malfunction, and the unit will recover when the temperature returns to normal.
• Do not leave the unit in a hot or cold location. Also, do not leave the unit in a location exposed to direct sunlight or near a
heater, as this may cause the cabinet to deform and the front panel to malfunction.
Storage temperature: f4°F to e140°F (f20°C to e60°C)
Specifi cations