29 E
Function
Command Direction
Parameter Reply Control/Response contents *
ALL RESET RSET W 0-
ADJUSTMENT LOCK ALCK WR 0-2 0-2 0: OFF, 1:ON 1, 2:ON 2 ○
OSD DISPLAY LOSD WR 0-2 0-2 0: ON 1, 1: OFF, 2: ON 2 ○
LED OFLD WR 0-1 0-1 0: ON, 1: OFF ○
TEMPERATURE ALERT TALT WR 0-2 0-2 0: OFF, 1: OSD & LED, 2: LED ○
STATUS ALERT SALT WR 0-2 0-2 0: OFF, 1: OSD & LED, 2: LED ○
OthersFunction
Command Direction
Parameter Reply Control/Response contents *
VOLUME VOLM WR 0-31 0-31 ○
BRIGHT VLMP WR 0-31 0-31 ○
TEMPERATURE SENSOR DSTA R 0Internal temperature normal
●
1Internal temperature abnormal has occurred and the monitor is in
standby mode
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION ERRT R Value Returns the temperature of the temperature sensor.
Indicates a temperature sensor abnormality when “126” is returned. ○
CAUSE OF LAST STANDBY MODE STCA W 0 Initialization
●
R0No detectable error has occurred
1 Standby mode by POWER button
2Main power off by the main power switch
3Standby mode by RS-232C
4Input signal waiting mode by No Signal
6Standby mode by abnormal temperature
20 Standby mode by OFF IF NO OPERATION setting
Controlling the Monitor with a PC (RS-232C)