N 108

SPECIFICATIONS

Measurement Conditions (unless otherwise specified): Line voltage 120 Vac, 60 Hz (SCM268) or 230 Vac, 50 Hz (SCM268E); full gain; 1 kHz, one channel

activated; source impedances: Mic 150 Ω, Aux Level 150 Ω; terminations: Line 600 Ω, Mic 600 Ω, Aux Out 10 kΩ. 12 V phantom power off.

ENGLISH

Frequency Response (Ref 1 kHz, controls centered)

Microphone Inputs: 150 Hz to 20 Khz ± 2 dB (built-in 80Hz low-cut)

Auxiliary Inputs: 20 Hz to 20 kHz ± 2 dB

Low-Cut Filter (Microphone inputs only)

3dB down at 80 Hz, 6 dB/octave

Gain (typical, controls full clockwise)

Input

 

Output

 

 

Mic

Line

Aux Out

 

 

 

 

Low-impedance mic

38 dB

76 dB

65 dB

(150 Ω)

 

 

 

Aux Level

3 dB

40 dB

29 dB

 

 

 

 

Inputs

Input

Impedance

 

 

Designed for

Actual

Input

 

use with

(typical)

Clipping Level

Mic

19-600 Ω

1.2 kΩ

–5 dBV

 

 

 

 

Aux Level

21 kΩ

>28 dBV

 

2 kΩ

 

 

Outputs

 

 

 

 

 

 

Output

Impedance

 

 

 

 

 

 

Designed for

Actual

Output

 

use with

(typical)

Clipping Level

Mic

low-Z inputs

0.2 Ω

–21 dBV

 

 

 

 

Line

>600 Ω

72 Ω

+18 dBV

 

 

 

 

Aux Out

>2 kΩ

870 Ω

+7 dBV

 

 

 

 

Total Harmonic Distortion

<0.25% at +4 dBu output level (through 22 Hz—22 kHz filter; Input 1 and Master centered, all other controls full counter- clockwise)

Equivalent Input Hum and Noise(150 Ω source; through 22

Hz—22 kHz filter) 124 dBV

Output Hum and Noise (through 22 Hz—22 kHz filter; chan- nel controls full counterclockwise)

Master full counterclockwise: –92 dBV

Master full clockwise: –70 dBV

Common Mode Rejection

>80 dB at 1 kHz

Polarity

All inputs to all outputs are non-inverting

Overload and Shorting Protection

Shorting outputs, even for prolonged periods, causes no dam- age. Microphone inputs are not damaged by signals up to +10 dBV; Auxiliary inputs by signals up to +36 dBV

Phantom Power

12 Vdc open-circuit through 340Ω series resistance

Operating Voltage

SCM268: 100—120 Vac rated nominal, 50/60 Hz, 60 mA

SCM268E: 220—240 Vac rated nominal, 50/60 Hz, 30 mA

Temperature Range

Operating: –7° to 49° C (20° to 120° F)

Storage: –29° to 74° C (–20° to 165° F)

Overall Dimensions

44 mm H x 218 mm W x 162 mm D (1.72 x 8.60 x 6.37 inches)

Net Weight

1.20Kg (2 lbs, 10 oz)

Certifications

SCM268: UL & cUL LISTED by Underwriters Laboratories, Inc.

SCM268E: Eligible to bear CE Marking. Conforms to European EMC Directive 89/336/EEC. Meets applicable tests and perfor- mance criteria in European Standard EN55103 (1996) parts 1 and 2, for residential (E1) and light industrial (E2) environ-

ments.

Replacement Parts

 

Knob, Master (blue)

95B8752

Knob, Channel Gain (white)

95A8752

Line (Power) Cords:

 

SCM268: 100-120 Vac (US/Canada)

95A8762

SCM268E: 220-240 Vac (EU)

95A8778

SCM268E (Australia/New Zealand)

95A9128

Fuse, SCM268 (5x20 mm,

 

250V, 80mA, slow-blow)

80A730

Fuse, SCM268E (5x20 mm,

 

250V, 40mA, slow-blow)

80J258

Hardware Kit

90AF8100

Link Bars (Bracket)

53A8443

Single Mount Bracket

53A8484

Dual Mount Bracket

53B8484

Optional Accessories

 

Line (Power) Cord, 230-240 Vac (UK)

95A8713