Power

The SM86 requires phantom power. This may be supplied to the microphone from an external power supply (such as the Shure model PS1A) or directly from preamplifiers, mixers, or consoles with built-in phantom power. Suitable sources should provide 11 to 52 Vdc phantom voltage.

Impedance

A load impedance of at least 600 Ohms is recommended. The load may be as low as 150 Ohms, but a reduction in output level and output clipping level will result.

SPECIFICATIONS

Transducer Type

Condenser (electret bias)

Frequency Response

50 to 18,000 Hz (see Figure 2)

Dynamic Range (1000 Ω)

124 dB (maximum SPL to A-weighted noise level)

Signal-to-Noise Ratio

71 dB at 94 dB SPL (IEC 651)*

*S/N ratio is difference between 94 dB SPL and equivalent SPL of self– noise A-weighted.

Polarity

Positive pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of the output connector. See Figure 4.

CAPACITOR (ELECTRET CONDENSER) CARTRIDGE

BLACK

FET IM-

 

DISCRETE

 

 

 

 

LF RESPONSE

RFI FILTER

2

1

 

PEDANCE CON-

CLASS A

 

 

 

 

FILTER

 

3

GREEN

VERTER

AMPLIFIER

 

 

 

 

 

 

REVERSE

VOLTAGE

PROTECTOR

SM86 BLOCK DIAGRAM

 

 

 

 

 

 

 

 

FIGURE 4

 

 

 

 

 

 

 

 

 

Power

 

 

+10

 

 

 

 

 

 

Phantom Supply Requirement . . . . . . . . 11 to 52 Vdc, positive

 

 

 

 

 

 

 

 

at both pins 2 and 3

dB

0

 

 

 

 

 

 

Current Drain

5.2 mA

 

 

 

 

 

 

 

 

Connector

 

 

–10

 

 

 

 

 

 

Three–pin (XLR) professional audio

 

 

 

 

 

 

 

 

 

Case

 

 

 

 

29 3

4 5 6789

2

3

4 5 6789

Dark gray enamel-painted steel with matte-finished silver

 

20

50

colored steel grille

 

 

100

1000

 

 

10000 20000

Dimensions

 

 

 

 

 

Hz

 

 

 

 

 

 

 

 

 

 

 

See Figure 5

 

 

 

 

 

 

 

 

 

 

TYPICAL FREQUENCY RESPONSE

FIGURE 2

Polar Pattern

Cardioid (see Figure 3)

250 Hz

2500 Hz

500 Hz

6400 Hz

1000 Hz

10000 Hz

TYPICAL POLAR PATTERN

FIGURE 3

Output Impedance

150 Ohms at 1 kHz

Recommended minimum load impedance: 600 Ohms

 

183 mm

 

(7.2 in.)

24 mm

49 mm

(.95 in.)

(1.92 in.)

OVERALL DIMENSIONS

FIGURE 5

Net Weight

Net: 278 grams (9.8 oz)

Environmental Conditions

Operating: –18°to 60° C (0° to 135° F) (relative humidity <90%)

Storage: –29°to 74° C (–20°to 165° F) (relative humidity <80%)

CERTIFICATION

Eligible to bear CE Marking. Conforms to European EMC Directive 89/336/EEC. Meets applicable tests and performance criteria in European Standard EN55103 (1996) parts 1 and 2, for residential (E1) and light industrial (E2) environments.

FURNISHED ACCESSORIES

Break Resistant Microphone Clip . . . . . . . . . . . . . . . . A25D Microphone Bag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26A13 5/8” to 3/8” Thread Adapter . . . . . . . . . . . . . . . . . 31A1856

Sensitivity (at 1,000 Hz)

Open Circuit Voltage . . . . . . . . . . . . . . . . –50 dBV/Pa (3.15 mV) (1 Pa = 94 dB SPL)

Output Clipping Level

1000 Ohm Load at 1,000 Hz . . . . . . . . . . . . . . +3 dBV (1.41 V)

OPTIONAL ACCESSORIES

Phantom Power Supply . . . . . . . . . . . . . . . . . . . . . . . . PS1A Shock StopperIsolation Mount . . . . . . . . . A55M, A55HM Popper StopperWindscreen . . . . . . . . . . . . . . . . A85WS 7.6 m (25 ft.) Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . C25F

Maximum SPL (at 1,000 Hz)

 

REPLACEMENT PARTS

 

1000 load (1% THD)

147 dB

Screen and Grille Assembly

RPM226

Self-Noise

 

Cartridge and Shock Mount

RPM112

23 dB typical, A-weighted

 

Replacement Amplifier Assembly

RPM410