PRIOREG 1 0x0074 4 bytes R/W 0x0000000F ....
... ... ....
... ... ....
PRIOREG15 0x00AC 4 bytes R/W 0x0000000F Priority register 15
Table 4: Overview of Interrupt Control Register
2.9.11 ICU Register Description
IRVEC R Addr.: 0x5000_0000 Default: 0xFFFF_FFFF
Description Interrupt vector register
Input with highest priority pending interrupt request
Bit No. Name Description
3:0 IRVEC For pending, valid interrupt: Binary code of input number.
Default vector: Bit[3:0] = 1
31:4 Vector ID For pending, valid interrupt: Bit[31:4] = 0.
Default vector: Bit[31:4] = 1
FIVEC R Addr.: 0x5000_0004 Default: 0xFFFF_FFFF
Description Fast interrupt vector register
Number of the highest-priority pending fast interrupt request
Bit No. Name Description
2:0 FIVEC For pending, valid interrupt: Binary code of FIQ number.
Default vector: Bit[2:0] = 1
31:3 Vector ID For pending valid Bit[31:3] = 0.
Default vector: Bit[31:3] = 1
LOCKREG R/W Addr.: 0x5000_0008 Default: 0x0000_0000
Description Priority lock register
Specification of a priority for blocking interrupt requests of lower and equal priority
Bit No. Name Description
3 – 0 LOCKPRIO Binary code of lock priority.
7 LOCKENABLE 0=Lock inactive / 1=Lock active
FIQ1SREG R/W Addr.: 0x5000_000C Default: 0x0000_0000
Description Fast interrupt request 1 select register
Declaration of an IRQ input as FIQ6 (input FIQ6 on FIQ interrupt controller)
Bit No. Name Description
3 – 0 FIQ1SREG Number of the input to be selected (binary code)
7 FIQ1SENABLE 0=Ignore FIQ declaration
0=Take into account FIQ declaration
FIQ2SREG R/W Addr.: 0x5000_0010 Default: 0x0000_0000
Description Fast interrupt request 2 select register
Declaration of an IRQ input as FIQ7 (input FIQ7 on FIQ interrupt controller)
Bit No. Name Description
3 – 0 FIQ2SREG Number of the input to be selected (binary code)
7 FIQ2SENABLE 0=Ignore FIQ declaration
0=Take into account FIQ declaration
IRQACK R Addr.: 0x5000_0014 Default: 0xFFFF_FFFF
Description Interrupt vector register with IRQ acknowledge
Confirmation of highest-priority pending interrupt request by reading
the associated interrupt vector
Bit No. Name Description
3 – 0 IRVEC Binary code of input number
31 - 4 Vector ID Valid IRQ vector: always ‘0’.
Default vector: always ‘1’ (also bits 3 – 0).
Copyright © Siemens AG 2007. All rights reserved. 27 ERTEC 200 Manual