11
ProLINE-RoadRunner Operator’s Guide A

Refer to the main Supervisor Menu

(2 pages back) for orientation.

1 Actuation duration is set by the Socket

Adapter.

For more information about menu

commands, see Chapter 3 of the

ProLINE-RoadRunner Owner’s

Manual.

• Light gray shaded fields
cannot be changed.
Opera tion
Job Pick Retries: 2
Error Retries: 3
Pocket Pitch: 4
Pocket Advance: 3
Head Velocity: 250
Accel: 700
Probes Puff: 50
Pick: 200
Place: 100
Travel: 250
Teach Tape: 40.0
Skt 1: -26.85
Reject: -166
Belt: -180
Restore Defaults
System
Time Hour: 4
Minute: 55
Month: 9
Day: 23
Year: 2002
Odometer Hours: 469.92
Devices: 24742
Timekeeping: OFF
Erase: 0.0s
Blankcheck: 0.0s
Program: 0.0s
Verify: 0.0s
Update
Software
Network Network Parm:NVRAM
Status: Enabled
PGM: Fred’sRR2
IP: 139.138.16.215
Prog Port: 7596
SUB: 255.255.248
GTW: 139.138.16.1
SNS: 0.0.0.0
Network
(cont.) SNS Port: 7500
HST: rr215.nt.data-io
DOM: nt.data-io.com
DNS: 139.138.16.105
DTS: 139.138.16.13
E_Addr:
0010EC002211
Clear NetParms
Configu-
ration Firmware Version
Ver 05.11.00.C
Installed Boards
Bkpln Brd Id: 2
Cntrl Brd Id: 1
Wvfrm Brd Id: 1
Adptr Brd Id: 3
Hardware Config
HwCfgIds 1, 3, 4
Model: name/name-
uC
System
Supervisor Menus, continued