TC12 Installation, Commissioning & Maintenance Handbook
666/HE/43100/000 Page 185 Issue 9
KAD 8 = 20 :sensor 8 is phase E, amber drive
Select normal lamp monitoring (not RLM) on vehicle phases:
Note: Sensors 3 to 9 do not monitor vehicle phases and so they are configured
for normal lamp monitoring by default - their configuration does not need
to be changed.
KRE 1 = 0 :sensor 1
KRE 2 = 0 :sensor 2
Turn off dim/bright checks:
KDP = 0
Example 3 - 4 phase controller
Description: Four phase intersection controller with two vehicle and two
pedestrian phases.
Each pedestrian phase is monitored with a single current sensor (see example 2
for separate wait and pedestrian monitoring using two current sensors per phase)
The configuration commands are detailed below.
Enable LMU write access:
AMB = 35
NEC = 249
Allocate function of current sensor 1 to 4:
KPT 1 = 1 :a vehicle phase
KPT 2 = 1 :a vehicle phase
KPT 3 = 12 :a pedestrian phase, including wait indicators
KPT 4 = 12 :a pedestrian phase, including wait indicators
Allocate aspect drive identity to each current sensor:
KAD 1 = 0 :sensor 1 is phase A
KAD 2 = 1 :sensor 2 is phase B
KAD 3 = 2 :sensor 3 is phase C
KAD 4 = 3 :sensor 4 is phase D
Select normal lamp monitoring (not RLM) on vehicle phases:
Note: Sensors 3 and 4 do not monitor vehicle phases and so their configuration
does not need to be changed.
KRE 1 = 0 :sensor 1
KRE 2 = 0 :sensor 2
UExample 4 - Pelican (single current sensor)
Description: This is a pelican controller with dimming.